Product Manual
3
EZ TRANSFER OPERATOR FIELD INSTALLATION KIT
(GENERAC MODEL NO. 05447)
Transfer Operator•
15A, 2-pole circuit breaker for Utility sensing•
125A Lower Panel Generator Circuit Switch•
Hold down bracket.•
Interlock Bar•
Mounting Hardware•
Decals •
Installation Guide•
GENREADY™ LOAD CENTER
FEATURES
200 amp main circuit breaker•
40 circuit capacity with the use of tandem breakers•
Dimensions are the same as a standard 42-space main load •
center
Utilizes standard Siemens components•
Split interior design allows for standby back-up power to user •
defined critical circuits.
- Lower, standby protected section has 18 one-inch spaces for
30 circuits
- Upper, utility only section has 10 one-inch spaces for 10
circuits
- An additional two spaces and two circuits are reserved for
generator installation (utility voltage sensing)
Circuits can easily be shifted from protected to non-protected •
and vice versa
UL listed and service entrance rated•
Models available with or without EZ Transfer operator factory •
installed
Single panels are compatible with generators rated up to 125 •
Amps/30 kW
Multiple GenReady load centers can be supported with a single •
generator
Flush Mount NEMA 1 or NEMA 3R enclosure depending on the •
model
Designed for use with Siemens, Generac, Centurion, and •
Guardian standby generators
Neutral and ground bars have multiple 1/0 conductor terminals•
The neutrals and grounds in the generator ready load center are •
NEC and UL Listed to accept multiple ground terminations in
one terminal*
* See the wiring diagram on the panel door for the latest product informa-
tion.
Figure 1 — GenReady Advanced Panelboard
with Operator
SPECIFICATIONS
LOAD CENTER
Enclosure .............................................. NEMA Type 1 or NEMA Type 3R,
general purpose, painted metal
Main Breaker .........................................................................200 Amp
Generator Switch ...................................................................125 Amp
Main breaker wire size ...................................... # 1 to 300 mcm Cu-Al
Generator switch wire size .............................# 2 to 1/0 Cu, 1/0-2/0 Al
Neutral Lug .................................................................# 6 to 300 mcm
Ground Lug ........................................................................... # 14- 2/0
Ground Fault or Arc Fault Circuit Breaker ...............QPF or QAF Siemens
Maximum number of circuits (standard 1" breakers /
tandem 1" breakers)
Protected circuits ......................................................................18/30
Non-protected circuits ............................................................. 10/NA
Total circuits .............................................................................28/40
Withstand rating Main bus (amps)..............................................22,000
Meets NEC wire bending space ........................................................Yes
UL listed ..........................................................................................Yes
Seismically qualified to meet UBC code ............................................Yes
Weight – GenReady Basic w/o EZ transfer operator
(GenReady Advanced with EZ transfer operator)..... 45.5 lbs. (49 lbs.)
Operating temperature range ........................................-20º F to 140º F
General Information