How to Guide
DESCRIPTION
The DLM Load Control Module is a 50 amp contact housed in a NEMA 3R enclosure for indoor and outdoor installation applications. Through the use of the
DLM Modules in conjunction with any of the 100-400 amp Nexus Smart Switches, household or business loads can be intelligently managed enabling the
use of a smaller, more efficient generator system. Up to four DLM Modules can be used with a single switch.
®
SPECIFICATIONS
Power Supply Source ................................................................................................... Contactor module is supplied with 120VAC from the load control module in the transfer switch.
Nominal Supply. ...............................................................................................................................................................................................................................................120VAC
Coil VA Inrush ........................................................................................................................................................................................................................................................... 30
Coil VA Sealed ......................................................................................................................................................................................................................................................... 6.5
Poles .......................................................................................................................................................................................................................................................................... 2
Voltages ........................................................................................................................................................................................................................................................... 120/240
Resistive Amps ......................................................................................................................................................................................................................................................... 50
F/L Inductive Amp ..................................................................................................................................................................................................................................................... 40
Locked Rotor Amps .....................................................................................................................................................................................................................................240@240V
UL 50 ...................................................................................................................................................................................................................................................................... Yes
GENERAC
®
STANDBY GENERATOR ACCESSORIES
DLM Load Control Module