Use and Care Guide
2
1.1 INTRODUCTION
This manual has been prepared especially for the purpose of famil-
iarizing personnel with the design, application, installation, opera-
tion and servicing of the applicable equipment. Read the manual
carefully and comply with all instructions. This will help to prevent
accidents or damage to equipment that might otherwise be caused
by carelessness, incorrect application, or improper procedures.
Every effort has been expended to make sure that the contents
of this manual are both accurate and current. The manufacturer,
however, reserves the right to change, alter or otherwise improve
the product at any time without prior notice.
1.2 UNPACKING
Carefully unpack the module. Inspect closely for any damage that
might have occurred during shipment. The purchaser must file with
the carrier any claims for loss or damage incurred while in transit.
1.3 EQUIPMENT DESCRIPTION
This Digital Load Module (DLM) is used to control or turn on and
off a load under the control of the Load Shed Module (LSM) in the
transfer switch.
The DLM consists of a 2-pole N.O. relay mounted in an enclosure.
The 2-pole relay is rated to control:
Current – 55 resistive or 40A inductive.•
Voltage – 600 Vac.•
Motor Rating – 3 hp @ 240 Vac.•
LRA – 240 Amps @ 240 Vac.•
Coil Voltage – 120 Vac (0.06A holding current)•
The enclosure is non-metallic and is rated UL type 3R.
A UL type 3R enclosure primarily provides a degree of protection
against falling rain and sleet; is undamaged by the formation of ice
on the enclosure. It is suitable for mounting indoors or outdoors.
The DLM module is UL listed as industrial control equipment, to
U.S. and Canadian safety standards.
Several crimp-on connectors are supplied for use in making the
contactor coil connections (1/4” quick connect) and grounding
terminal connections (1/4” ring terminals). Note: Use yellow
colored insulator terminals for #10-#12 AWG wire, blue colored
insulator terminals for #14-16 AWG wire.
1.4 TRANSFER SWITCH DATA
DECAL
A DATA DECAL is permanently affixed to the DLM enclosure. Use
this DLM only within the specific limits shown on the DATA DECAL
and on other decals and labels that may be affixed. This will pre-
vent damage to equipment and property.
When requesting information or ordering parts for this equipment,
make sure to include all information from the DATA DECAL.
Record the Model number in the space provided below for future
reference.
MODEL #
1.5 SAFE USE OF DLM
Before installing, operating or servicing this equipment, read the
SAFETY RULES (inside front cover) carefully. Comply strictly with
all SAFETY RULES to prevent accidents and/or damage to the
equipment. Also, be sure to read all instructions and information
found on tags, labels and decals affixed to the equipment.
A publication that outlines the safe use of DLM is:
NFPA 70; National Electrical Code•
NOTE:
It is essential to use the latest version of any standard to ensure
correct and current information.
General Information