Use and Care Manual

Maintenance
22 EcoGen Automatic Standby Generator Owner’s Manual
Figure 4-3. Exploded View – EcoGen Oil System Drain Pump Kit
EcoGen Oil System Drain Pump Kit Parts List (Kit Part No. 0K3717)
1. ¼ in. Rubber Hose*
2. ½ in. Spring Clamp*
3. ¾ in. Spring Clamp**
4. ½ in. Rubber Hose**
5. Drill Pump
6. ¼ in. Barb Hose Fitting w/¾ in. Hose Thread*
7. ½ in. Barb Hose Fitting w/¾ in. Hose Thread**
* Parts 1, 2, and 6 come assembled from the supplier.
** Parts 3, 4, and 7 come assembled from the supplier.
EcoGen Oil System Drain Pump Assembly
1. Install the ¼ in. Hose Assembly onto the inlet side of the Drill Pump. Twist the fitting clockwise until it is snug. Do
not over-tighten. See A of Figure 4-4.
2. Install the ½ in. Hose Assembly onto the outlet side of the Drill Pump. Twist the fitting clockwise until it is snug. Do
not over-tighten. See B of Figure 4-4.
1
2
6
5
7
4
3
*1, 2, and 6