Use and Care Manual
Troubleshooting
EcoGen Automatic Standby Generator Owner’s Manual 33
MISWIRE RED Unit will not start in AUTO with 2-
wire start signal.
Check the
LEDs/Screen
for alarms.
Contact servicing dealer.
OVERVOLTAGE RED Unit will not start in AUTO with 2-
wire start signal.
Check the
LEDs/Screen
for alarms.
Contact servicing dealer.
LOW BATTERY YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Clear alarm. Navigate to the BATTERY
MENU on the control pad LCD. Contact
servicing dealer if battery is GOOD.
Replace battery If CHECK BATTERY is
displayed.
BATTERY
PROBLEM
YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Contact servicing dealer.
CHARGER
WARNING
YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Contact servicing dealer
SERVICE A YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Perform SCHEDULE A maintenance.
Press ENTER to clear.
SERVICE B YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Perform SCHEDULE B maintenance.
Press ENTER to clear.
INSPECT
BATTERY
YELLOW Yellow LED illuminated in any
state.
Check screen
for additional
information.
Inspect battery. Press ENTER to clear.
Table 5-2. Generator Alarm Diagnostics (Continued)
Active Alarm LED Problem
Things to
Check
Solution