Use and Care Manual
Installation Diagrams
38 EcoGen Automatic Standby Generator Owner’s Manual
6.2 — Off Grid Mode Application Schematic
HOUSE
LOADS*
ENGINE
CONTROLLER
VOLTAGE
REGULATOR
(AVR)
ENGINE
START
BATTERY
CHARGER
12 VOLT
ENGINE
START
BATTERY
ALTERNATOR
BATTERY
CHARGER
INVERTER
TWO-WIRE
START
BATTERY
VOLTAGE
SENSING
AC
DISTRIBUTION
PANEL
120/240V
DC
DISTRIBUTION
PANEL
12V/24V/48V
BATTERY
12V/24V/48V
INVERTER/CHARGER
*House Loads must be less than 10 kW or 2 hp
GENERATOR
HOUSE
HOUSE
LOADS*
120V/240V
CHARGER
SUPPLY
TWO-WIRE
START
TWO-WIRE
START
24/48V
DC
12/24/36/48V
DC
WIND
TURBINE
PHOTO
VOLTAIC
PANEL
120/240V
OUTPUT
ECOGEN - TYPICAL OFF-GRID APPLICATION SYSTEM
DIAGRAM