Replacement Part List

6 of 11
25 & 30 kW installation layout
Protector
®
Series
Drawing #0K8420-B (1 of 2)
1490 [58.7] TYP
48
[1.9]
TYP
980
[38.6]
OVERALL
HEIGHT
44 [1.7]
631 [24.8]
DOOR TYP
665.5 [26.2"]
CENTER OF GRAVITY
(SEE NOTE 5)
45
[1.8]
TYP
780 [30.7]
776
[30.6]
OVERALL WIDTH
1580 [62.2]
OVERALL LENGTH
SERVICE ITEM 1.5L
OIL FILL CAP EITHER DOOR
OIL DIP STICK RIGHT DOOR
OIL FILTER RIGHT DOOR
OIL DRAIN HOSE RIGHT DOOR
RADIATOR DRAIN HOSE RIGHT DOOR
AIR CLEANER ELEMENT RIGHT DOOR
SPARK PLUGS RIGHT DOOR
MUFFLER SEE NOTE 12
FAN BELT EITHER DOOR
BATTERY RIGHT DOOR
WEIGHT DATA
ENGINE/KW
ENCLOSURE
MATERIAL
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
SHIPPING WEIGHT
KG [LBS]
1.5L/25KW ST 392 [865] 30 [66] 422 [931]
1.5L/30KW ST 406 [895] 30 [66] 436 [961]
1.5L/25KW AL 352 [777] 30 [66] 382 [843]
1.5L/30KW AL 366 [807] 30 [66] 396 [873]
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1887 (74.3") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES.
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. EXHAUST SYSTEM MAXIMUM BACK PRESSURE: 24 INCHES H2O.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
10. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
11. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
12. EXHAUST MUFFLER ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE ENCLOSURE TO ACCESS EXHAUST MUFFLER.
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
AIR INTAKE
(BOTH SIDES)
REFERENCE OWNERS MANUAL
FOR PERIODIC
REPLACEMENT PART LISTINGS.
REAR VIEW
CIRCUIT BREAKER
SEE NOTE 3
RIGHT SIDE VIEW
FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
VISE ACTION LATCH,
ONE PER DOOR, ONE LIFT-OFF
DOOR PER SIDE OF GENERATOR.
LEFT SIDE VIEW
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
LIFTING PROVISION (4 PLACES)
SEE NOTES 5, 8 AND
CENTER OF GRAVITY
DIMENSIONS.
RADIATOR/EXHAUST
DISCHARGE AIR
TOP VIEW
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
BATTERY 12V
GROUP 26
NEGATIVE GROUND
P/N: 077483
CIRCUIT BREAKER
NEUTRAL AND CUSTOMER
CONNECTION OPENING