Owner's Manual

Owner’s Manual for Portable Generator 5
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
that this engine/equipment complies with
exhaust and evaporative emissions stan-
dards. Locate the emissions compliance decal
on the engine to determine applicable stan-
dards. For emissions warranty information,
please reference the included emissions war-
ranty. It is important to follow the maintenance
specifications in the manual to ensure that the
engine complies with the applicable emissions
standards for the duration of the product’s life.
TABLE 2. Product Specifications
Generator Specifications
Rated Power 3.3 kW**
Surge Power 3.75 kW
Rated AC Voltage 120/240
Rated AC Load
Current @ 240V
Current @ 120V
13.75 Amps**
27.5 Amps**
Rated Frequency 60 Hz @ 3600 RPM
Phase Single Phase
Generator Dry Weight (assembled) 111.4 lbs. (50.5 kg)
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement 208 cc
Spark Plug Part No. 0H33750169
Spark Plug Type F6TC, NGK BP6IS or Champion RN11YC
Spark Plug Gap 0.030 inch (0.76 mm)
Gasoline Capacity 3.35 gal (12.7 L)
Oil Type
See Chart in the
Add Engine Oil Section
Oil Capacity 0.634 qt (0.6 L)
Run Time at 50% Load 10.2 Hours
* Go to Generac.com or contact an IASD for replacement parts.