Product Manual B

Customer Driven • Unsurpassed Value
215 Power Drive . Berlin, WI 54923-2420 . Phone: 800-926-9768 . Fax: 920-361-2214
magnumpower.com
Page 1 of 4
6/14
Magnum Vertical Mast Light Tower – MLT4080KV
Specifications
ENGINE
Kubota
®
D1105-E3BG - liquid cooled, diesel engine
o Standby - 15.4 hp @ 1800 rpm
o Prime - 13.5 hp @ 1800 rpm
o 3 cylinder
o 1.12 L displacement
Fuel consumption (prime) – 0.70 gph (2.65 Lph)
60 Hz engine/generator
Industrial engine exhaust system
Rubber vibration dampers isolate engine/generator from frame
Cooling system capable of operating at 120°F ambient
Full flow oil filter, spin on type
Fuel filter with replaceable element
Dry type cartridge air filter
Polyethylene fuel tank with large diameter opening
o 56 gal. capacity
o 88 hr. run capacity
o 3 ½” fill port
ENGINE CONTROLS
Engraved, aluminum punched and anodized control panel
Four position keyed switch – glow plugs (preheat, off, run, start)
Hour meter
Automatic low oil/high temperature shutdown system
GENERATOR
Marathon Electric
®
o Brushless
8 kW standby output
120/240 VAC – 66/33A
+/-6% capacitor voltage regulation
ELECTRICAL SYSTEM AND CONTROLS
Single toggle switch for raising /lowering vertical mast
Individual floodlight circuits with 15A breakers
Ballast indicator lights
40A start limit breaker (assures no load condition exists before starting)
Standard individually breakered convenience outlets:
o (2) 120 VAC 20 Amp GFCI duplex outlets (Nema 5-20R type)
o (1) 240 VAC 30 Amp twistlock outlets (Nema L6-30R type)
440 CCA wet cell battery