Specifications

DRY PRIME
MOBILE TRASH PUMPS
10/2015 Rev A. 0L6299
©2015 Generac Power Systems, Inc. All Rights Reserved.
Specifications are subject to change without notice.
Generac Power Systems, Inc.
S45 W29290 Hwy. 59, Waukesha, WI 53189
generacmobileproducts.com 1-888-GENERAC (1-888-436-3722)
Features
Final Tier 4 engine
Large, back-lit 4.3” LCD display
Automatic start/stop control for use with two-switch inputs
High efficiency pump end
Run-dry system for continuous operations without need for external flush water or venting
High performance priming system (Diaphragn or Venturi)
SERIES
SPECIFICATIONS
MTP4000DZD | MTP4000DZV MTP6000DZD | MTP6000DZV
Flow
Pump Output: gpm (Lpm) 1450 (5489) 2750 (10409)
Total Dynamic Head: ft (m) 165 (50.29) 150 (46)
Max. Solid Diameter: in (mm) 3 (76.2) 3 (76.2)
Max. Lift Suction: ft (m) 28 (8.5) 28 (8.5)
Pump
Brand Cornell Pump Cornell Pump
Fitting Size: in 4 NPTF 6 NPTF
Priming System (Diaphragm or Venturi) 50 SCFM 13.2 CFM 50 SCFM 13.2 CFM
Engine
Brand Deutz D 2.9 L4 Deutz TD 2.9 L4
Type Water-cooled, naturally aspirated, 4 cylinder Water-cooled, turbo-charged, 4 cylinder
Operating Speed: rpm 2600 2600
Tier Final 4 Final 4
Controller LOFA CP750 LOFA CP750
Capacities
Fuel Tank Capacity: gal (L) 110 (416) 110 (416)
Maximum Run Time: hr 32 26
Trailer
Tongue Flip-tongue design Flip-tongue design
Axle: lbs (kg) 1 - 5000 (2268) 1 - 5000 (2268)
Brakes Electric Electric
Standard Hitch 2” Ball 2” Ball