Magnum Vertical Mast Light Tower – MLT4060MV
Specifications
ENGINE
• Mitsubishi
®
L3E-W461ML - liquid cooled, diesel engine
o Standby - 12.2 hp @ 1800 rpm
o Prime - 10.5 hp @ 1800 rpm
o 3 cylinder
o 0.95 L displacement
• Fuel consumption (prime) – 0.47 gph (1.78 Lph)
• 60 Hz engine/generator
• Industrial engine exhaust system
• Rubber vibration dampers isolate engine/generator from frame
• Cooling system capable of operating at 120°F ambient
• Full flow oil filter, spin on type
• Fuel filter with replaceable element
• Dry type cartridge air filter
• Polyethylene fuel tank with large diameter opening
o 56 gal. capacity
o 119 hr. run capacity
o 3 ½” fill port
ENGINE CONTROLS
• Engraved, aluminum punched and anodized control panel
• Four position keyed switch – glow plugs (preheat, off, run, start)
• Hour meter
• Automatic low oil/high temperature shutdown system
GENERATOR
• Marathon Electric
®
o Brushless
• 6 kW standby output
• 120/240 VAC – 50/25A
• +/-6% capacitor voltage regulation
ELECTRICAL SYSTEM AND CONTROLS
• Single toggle switch for raising /lowering vertical mast
• Individual floodlight circuits with 15A breakers
• Ballast indicator lights
• 30A start limit breaker (assures no load condition exists before starting)
• Standard individually breakered convenience outlets:
o (1) 120 VAC 20 Amp GFCI duplex outlets (Nema 5-20R type)
o (1) 240 VAC 30 Amp twistlock outlets (Nema L6-30R type)
• 440 CCA wet cell battery