Product Manual B
Customer Driven • Unsurpassed Value
215 Power Drive . Berlin, WI 54923-2420 . Phone: 800-926-9768 . Fax: 920-361-2214
magnumpower.com
Page 1 of 4
6/14
Magnum Light Tower – MLT5080 Specifications
ENGINE
• Kubota
®
D1105-E3BG - liquid cooled, diesel engine
o Standby - 15.4 hp @ 1800 rpm
o Prime - 13.5 hp @ 1800 rpm
o 3 cylinder
o 1.12 L displacement
• Fuel consumption (prime) – 0.70 gph (2.65 Lph)
• 60 Hz engine/generator
• Industrial engine exhaust system
• Rubber vibration dampers isolate
engine/generator from frame
• Cooling system capable of operating at 120°F
ambient
• Full flow oil filter, spin on type
• Fuel filter with replaceable element
• Dry type cartridge air filter
• Polyethylene fuel tank with large diameter
opening
o 56 gal. capacity
o 80 hr. run capacity
o 3 ½” fill port
ENGINE CONTROLS
• Engraved, aluminum punched and anodized control panel
• Four position keyed switch – glow plugs (preheat, off, run, start)
• Hour meter
• Automatic low oil/high temperature shutdown system
GENERATOR
• Marathon Electric
®
o Brushless
• 8 kW standby output
• 120/240 VAC – 66/33A
• +/-6% capacitor voltage regulation
ELECTRICAL SYSTEM AND CONTROLS
• Individual floodlight circuits with 15A breakers
• Ballast indicator lights
• Four cylindrical ballasts
• Individually canned transformers for proper heat dissipation
• 40A start limit breaker (assures no load condition exists before starting)