Product Manual B

Customer Driven • Unsurpassed Value
215 Power Drive . Berlin, WI 54923-2420 . Phone: 800-926-9768 . Fax: 920-361-2214
magnumpower.com
Page 1 of 4
6/14
Magnum Light Tower – MLT5080 Specifications
ENGINE
Kubota
®
D1105-E3BG - liquid cooled, diesel engine
o Standby - 15.4 hp @ 1800 rpm
o Prime - 13.5 hp @ 1800 rpm
o 3 cylinder
o 1.12 L displacement
Fuel consumption (prime) – 0.70 gph (2.65 Lph)
60 Hz engine/generator
Industrial engine exhaust system
Rubber vibration dampers isolate
engine/generator from frame
Cooling system capable of operating at 120°F
ambient
Full flow oil filter, spin on type
Fuel filter with replaceable element
Dry type cartridge air filter
Polyethylene fuel tank with large diameter
opening
o 56 gal. capacity
o 80 hr. run capacity
o 3 ½” fill port
ENGINE CONTROLS
Engraved, aluminum punched and anodized control panel
Four position keyed switch – glow plugs (preheat, off, run, start)
Hour meter
Automatic low oil/high temperature shutdown system
GENERATOR
Marathon Electric
®
o Brushless
8 kW standby output
120/240 VAC – 66/33A
+/-6% capacitor voltage regulation
ELECTRICAL SYSTEM AND CONTROLS
Individual floodlight circuits with 15A breakers
Ballast indicator lights
Four cylindrical ballasts
Individually canned transformers for proper heat dissipation
40A start limit breaker (assures no load condition exists before starting)