LINE DIAGRAMS PWR CELL - A0000521683

Protected Loads / Existing Generator
- 1 PWRcell Inverter - 1 CT Kit (included)
- 6 PV Links
- 1 PWRcell Battery
This design shows a PWRcell system configured with a
non-Generac generator. This design isolates the generator from
the inverter and involves a line-side tap and two transfer
switches. The inverter output supports a loads panel that can
also be transferred to the generator. This design is suitible for
most residential 120 V / 240 V services.
Reference Code: DSLD00005-02
Page 10 of 19
Generac Power Systems, Inc.• S45 W29290 Hwy. 59 • Waukesha, WI 53189© 2022 Generac Power System, Inc. All rights reservedPart No. A0000521683 | Rev. H | 18 JAN 2022
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product documentation for additional installa-
tion details and requirements.
*Install SnapRS in PV array for module-level PVRSS requ-
-irements, one SnapRS per PV module.
CAT5
Comms Wiring
Control Wiring
DC Wiring (excluding REbus)
AC Wiring
Powered by REbus
TM
(DC Nanogrid)
Generac
PowerCore
30 A
30 A
30 A
30 A
Power Conversion
PWRcell
TM
Inverter
Router
50 A
Ethernet
Main Distribution
Panel
AC Grid
M
Protected Loads Panel
Gen
Service Rated
Automatic
Transfer
Switch
N
E
T
N
E
T
Manual
Transfer
Switch
CTs
40 A
OCPD
NOTE: The generator does not
charge PWRcell Battery or
parallel output with the inverter.
NOTE: For load sizing,
max continuous current
is 32 A.
Storage
PWRcell Battery
PV Optimization
PV Link
TM
Substring Optimizer
PV Array