LINE DIAGRAMS PWR CELL - A0000521683

Protected Loads / 100 A Service Panel Upgrade
- 1 PWRcell Inverter - 1 CT Kit (included)
- 3 PV Links (max 6)
- 1 PWRcell Battery
This design shows a PWRcell system with a Protected Loads
panel. Install a service-rated panel rated for 125 A. Use a 100 A
main breaker recognized by the panel manufacturer as
compatible per product listing(s). This design is suitable for
most residential 120 V / 240 V services.
Reference Code: DSLD00023-01
Page 05 of 19
Generac Power Systems, Inc.• S45 W29290 Hwy. 59 • Waukesha, WI 53189© 2022 Generac Power System, Inc. All rights reservedPart No. A0000521683 | Rev. H | 18 JAN 2022
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product documentation for additional installa-
tion details and requirements.
*Install SnapRS in PV array for module-level PVRSS requ-
-irements, one SnapRS per PV module.
CAT5
Comms Wiring
Control Wiring
DC Wiring (excluding REbus)
AC Wiring
Powered by REbus
TM
(DC Nanogrid)
Generac
PowerCore
30 A
30 A
30 A
30 A
Power Conversion
PWRcell
TM
Inverter
Router
50 A
Ethernet
M
AC Grid
Protected Loads Panel
40 A
CTs
NOTE: For load sizing,
max continuous current
is 32 A.
125 A Main
Distribution Panel
100 A
NOTE: Replace 125 A Breaker
with 100 A Service-Rated
Breaker. Busbar must be
rated for 125 A.
Storage
PWRcell Battery
PV Array
PV Optimization
PV Link
TM
Substring Optimizer