LINE DIAGRAMS PWR CELL - A0000521683
Table Of Contents
- 1_DSLD00002-02 (1111)
- 2_DSLD00003-02 (0312)
- 3_DSLD00006-02 (1312)
- 4_DSLD00001-02 (131E)
- 5_DSLD00023-01 (131T)
- 6_DSLD00004-02 (1313)
- 7_DSLD00007-02 (2412)
- 8_DSLD00010-02 (2324)
- 9_DSLD00009-02 (2318)
- 10_DSLD00005-02 (231B)
- 11_DSLD00026-01 (131N)
- 12_DSLD00014-03 (2315)
- 13_DSLD00015-03 (231F)
- 14_DSLD00016-03 (241A)
- 15_DSLD00024-01 (131U)
- 16_DSLD00025-02 (231V)
- 17_DSLD00021-02 (031Q)
- 18_DSLD00019-03 (031P)
- 19_DSLD00020-03 (031R)
Protected Loads / Multi-System
- 2 PWRcell Inverters - 2 CT Kits (included)
- 6 PV Links (max. 6/Inv)
- 2 PWRcell Batteries
This design shows a multi-system Generac PWRcell solution.
Both inverter systems have solar and energy storage. Inverters
must support separate loads panels and must not have their
Protected Loads outputs coupled. This design is suitible for
most residential 120 V / 240 V services.
Reference Code: DSLD00010-02
Page 08 of 19
Generac Power Systems, Inc.• S45 W29290 Hwy. 59 • Waukesha, WI 53189© 2022 Generac Power System, Inc. All rights reservedPart No. A0000521683 | Rev. H | 18 JAN 2022
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product documentation for additional installa-
tion details and requirements.
*Install SnapRS in PV array for module-level PVRSS requ-
-irements, one SnapRS per PV module.
CAT5
Comms Wiring
Control Wiring
DC Wiring (excluding REbus)
AC Wiring
Powered by REbus
TM
(DC Nanogrid)
Pika
PowerCore
Pika
PowerCore
Router
30 A
30 A
30 A
30 A
50 A
Generac
PowerCore
30 A
30 A
30 A
30 A
50 A
Generac
PowerCore
Power Conversion
PWRcell
TM
Inverter
CTs
Router
Ethernet
Ethernet
CTs
Main Distribution
Panel
40 A
40 A
AC Grid
M
AC
Combiner Panel
Protected Loads Panel
Protected Loads Panel
NOTE: For load sizing, max
continuous current is 32 A.
Storage
PWRcell Battery
PV Array
PV Optimization
PV Link
TM
Substring Optimizer