LINE DIAGRAMS PWR CELL - A0000521683
Table Of Contents
- 1_DSLD00002-02 (1111)
- 2_DSLD00003-02 (0312)
- 3_DSLD00006-02 (1312)
- 4_DSLD00001-02 (131E)
- 5_DSLD00023-01 (131T)
- 6_DSLD00004-02 (1313)
- 7_DSLD00007-02 (2412)
- 8_DSLD00010-02 (2324)
- 9_DSLD00009-02 (2318)
- 10_DSLD00005-02 (231B)
- 11_DSLD00026-01 (131N)
- 12_DSLD00014-03 (2315)
- 13_DSLD00015-03 (231F)
- 14_DSLD00016-03 (241A)
- 15_DSLD00024-01 (131U)
- 16_DSLD00025-02 (231V)
- 17_DSLD00021-02 (031Q)
- 18_DSLD00019-03 (031P)
- 19_DSLD00020-03 (031R)
Protected Loads / Reveue Grade Meter
- 1 PWRcell Inverter - 1 CT Kit (included)
- 6 PV Links - 1 PWRcell ATS
- 1 PWRcell Battery
This design shows a PWRcell system with a revenue grade
meter (RGM) connected for participation in a solar incentive
program. Use this system configuration to maximize solar
incentive credit and provide backup power to a protected loads
panel. This design is suitable for most residential 120 V / 240 V
services.
Reference Code: DSLD00009-02
Page 09 of 19
Generac Power Systems, Inc.• S45 W29290 Hwy. 59 • Waukesha, WI 53189© 2022 Generac Power System, Inc. All rights reservedPart No. A0000521683 | Rev. H | 18 JAN 2022
FOR REFERENCE ONLY; NOT FOR CONSTRUCTION.
*Installer responsible for code compliance.
*Refer to product documentation for additional installa-
tion details and requirements.
*Install SnapRS in PV array for module-level PVRSS requ-
-irements, one SnapRS per PV module.
CAT5
Comms Wiring
Control Wiring
DC Wiring (excluding REbus)
AC Wiring
Powered by REbus
TM
(DC Nanogrid)
Generac
PowerCore
30 A
30 A
30 A
30 A
Power Conversion
PWRcell
TM
Inverter
Router
50 A
Ethernet
40 A
200 A
Main
Distribution
Panel
AC Grid
M
Protected
Loads Panel
RGM
PWRcell
ATS
N
E
T
CNTRL
ATS
CTs
NOTE: For load sizing,
max continuous current
is 32 A.
Storage
PWRcell Battery
PV Optimization
PV Link
TM
Substring Optimizer
PV Array










