Owner’s Manual Generac PWRcell® Battery ON OFF BATTERY DISCONNECT 0011031 WARNING Loss of life. This product is not intended to be used in a critical life support application. Failure to adhere to this warning could result in death or serious injury. (000209b) Register your Generac product at: https://pwrfleet.generac.com 1-888-GENERAC Register (888-436-3722) your Generac product at: WWW.GENERAC.COM Para español, visita: http://www.generac.
Use this page to record important information about your Generac Product Record the information found on your unit data label on this page. See Specifications. When contacting an Independent Authorized Service Dealer (IASD) or Generac Customer Service, always supply the complete model number and serial number of the unit. Operation and Maintenance: Proper maintenance and care of the energy storage system ensures a minimum number of problems and keeps operating expenses at a minimum.
Table of Contents Section 1:Safety Rules & General Information Introduction ..........................................................1 Read This Manual Thoroughly ....................................1 Safety Rules .........................................................1 How to Obtain Service ................................................1 General Hazards ..................................................2 Electrical Hazards ................................................3 Battery Hazards ...........
This page intentionally left blank.
Safety Rules & General Information Section 1: Safety Rules & General Information Introduction Thank you for purchasing a Generac PWRcell® product. This owner’s manual includes full details on the use, operation, and maintenance of the PWRcell Battery. The companion document to this manual is the Generac PWRcell Battery Installation Manual.
Safety Rules & General Information General Hazards • Connecting the PWRcell system to the electric util- DANGER Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. (000191) WARNING Risk of injury. Do not operate or service this machine if not fully alert. Fatigue can impair the ability to operate or service this equipment and could result in death or serious injury. (000215a) WARNING Loss of life.
Safety Rules & General Information Electrical Hazards Battery Hazards WARNING DANGER Electrocution. Water contact with a power source, if not avoided, will result in death or serious injury. (000104) Explosion. Do not dispose of batteries in a fire. Batteries are explosive. Electrolyte solution can cause burns and blindness. If electrolyte contacts skin or eyes, flush with water and seek immediate medical attention. (000162) DANGER Electrocution.
Safety Rules & General Information Safety Precautions Symbols Warning symbols are used to warn of the conditions that may cause severe injury or damage to equipment. The following table describes the warning symbols used in the equipment's markings and within this document. This equipment contains high voltage which can cause electric shock resulting in severe injury. Ensure polarity of connections during assembly. Keep equipment away from open flame or ignition sources.
General Information Section 2: General Information PWRcell Battery Naming Convention PWRcell PRODUCT SERIES PWRcell Series ENCLOSURE TYPE IR - Indoor Rated OR - Outdoor Rated IR M3 DCB BATTERY SERIES DCB EX NUMBER OF BATTERY MODULES 3 - Three Modules 4 - Four Modules 5 - Five Modules 6 - Six Modules 012273 Owner’s Manual for Generac PWRcell Battery 5
General Information Specifications CAUTION Ensure all battery modules installed in any single PWRcell Battery are the same type (EX or DCB). Connecting different battery types can result in equipment damage. (000731a) Description Units PWRcell M3 PWRcell M4 PWRcell M5 PWRcell M6 kWh 9 12 15 18 Nominal Cont. AC Power* kW 3.4 4.5 5.6 6.7 Max. Cont. AC Power** kW 4.5 6 7.5 9 A 11.6 15.5 19.4 23.3 A, RMS 25 33 42 50 – 3 4 5 6 Energy Usable Energy Power Max. Cont.
General Information Serial Number Location Unit Dimensions Indoor Rated Unit Dimensions CAUTION Ensure all battery modules installed in any single PWRcell Battery are the same type (EX or DCB). Connecting different battery types can result in equipment damage. (000731a) Refer to Figure 2-1 to locate serial numbers for the unit (A) and the individual battery modules (B).
General Information Component Locations ON NOTE: Turn Battery Disconnect OFF whenever the system will be powered down and left inactive for an extended period of time to prevent battery discharge. OFF BATTERY DISCONNECT Battery Status LED A See Figure 2-4. The color and strobing interval of LED (B) communicates battery status. E B Table 2-1.
General Information . C F E G A D B B B H D 009893 Figure 2-5. Generac PWRcell System Example A B C D Solar Panels PV Link PWRcell Battery REbus E F G H PWRcell Inverter Grid Loads Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Line Carrier (PLC) communication. No additional communication wiring or equipment is required for communication between a PWRcell Inverter, PV array, and / or other REbus enabled batteries.
General Information Table 2-2. Battery State of Charge Setpoints Setpoint Behavior Shut off point where the battery stops discharging during a utility service interruption. When battery SoC reaches this value, the battery will go to sleep. The battery will charge again as soon as power is available on REbus. If the grid is not present and the system was islanding, the system will perform a Power Search every hour for four minutes. See Power Search. Min Absolute • Default value is 2%.
General Information Battery Settings Table 2-3. Battery Settings Setpoint Range Default Description PLM Channel 1 – 12 1 Channel for REbus communications. All devices in a system must use the same channel (except REbus Beacon). MinSocAbsl 0 – 20% 2 Minimum state of charge (SOC) absolute- this is the percentage of charge the battery will discharge to while the system is islanded.
General Information Island Mode In the event of a grid outage, the PWRcell Inverter enters Island Mode. While in Island Mode, the inverter disconnects from the utility grid and powers the building from the REbus nanogrid. In a typical solar-plus-storage configuration, this means all REbus-connected batteries will work together with the PV links to supply power to REbus. The inverter will pull power from REbus to provide AC power to protected loads.
General Information System Recovery During a Utility Grid Outage If during a utility service interruption, the PWRcell system stops powering backup loads, refer to Table 2-5. NOTE: Please read sections on Island Mode, Sleep Mode, and Power Search for complete understanding of system performance during a utility grid outage. Table 2-5. System Recovery Problem Possible Cause Solution During an extended grid outage the system turned off.
General Information System Blackstart By manually enabling the battery using the Battery Disconnect Switch, it is possible to perform what is called a Blackstart on the PWRcell system. IMPORTANT: Performing a Blackstart of the system will cancel a Shutdown initiated at the inverter and reenergize REbus DC wiring. NOTE: Blackstart battery voltage must be 13V or greater to power the system. See Service for more information. See Figure 2-8.
Maintenance Section 3: Maintenance General Upkeep • Keep the area around the PWRcell Battery neat and clean at all times. Ensure surrounding area is free of snow, sand, leaves, branches, pet hair, or other debris that could obstruct airflow in or out of the unit. Inspecting Vents See Figure 3-1. Verify intake vent (A) and exhaust vent (B) are clear at all times. • Do not store items on top of, under, leaning B against, or propped up where they might fall on the PWRcell Battery.
Maintenance Cleaning Outlet Vent Decommissioning Clean outlet vent (A) with dry cloth or shop vacuum. WARNING Environmental Hazard. Always recycle batteries at an official recycling center in accordance with all local laws and regulations. Failure to do so could result in environmental damage, death, or serious injury. (000228) WARNING A 011214 Figure 3-3. Cleaning Outlet Vent Service DANGER Electrocution. PWRcell Battery front cover should be removed by a qualified technician only.
Maintenance This page intentionally left blank.
Maintenance This page intentionally left blank.
This page intentionally left blank.
® Part No. A0000639747 Rev. C 04/5/2021 ©2021 Generac Power Systems, Inc. All rights reserved. Specifications are subject to change without notice. No reproduction allowed in any form without prior written consent from Generac Power Systems, Inc. Generac Power Systems, Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189 1-888-GENERAC (1-888-436-3722) www.generac.