Product Specifications
7.6kW 1Ø PWRcell Inverter with CTs
Model #: X7602 (Ordering SKU: APKE00014)
11.4 kW 3Ø PWRcell Inverter with CTs
Model #: X11402 (Ordering SKU: APKE00013
Solar + storage is simple with the Generac PWRcell™ Inverter. This bi-directional, REbus™-powered
inverter oers a simple, ecient design for integrating smart batteries with solar. Ideal for self-supply,
backup power, zero-export and energy cost management, the PWRcell Inverter is the industry’s most
feature-rich line of inverters, available in single-phase and three-phase models.
FEATURES & BENEFITS
• Single inverter for grid-tied solar with smart battery integration
• Simplified system design: No autotransformer or battery inverter needed
• User-selectable modes for backup power, self-supply, time-of-use, zero-import and export limiting
• Free system monitoring included via PWRview™ Web Portal and Mobile App
AC OUTPUT/GRID-TIE
M O D E L
X7602
M O D E L
X11402
MAX. CONT. GRIDTIED AC POWER @ 50°C 122°F: 7600 W 11400 W
AC OUTPUT VOLTAGE: 120/240, 1Ø VAC 120/208, 3Ø VAC
AC FREQUENCY: 60 Hz 60 Hz
MAXIMUM CONTINUOUS OUTPUT CURRENT: 32 A, RMS 32 A, RMS
GROUNDFAULT ISOLATION DETECTION: Included Included
CHARGE BATTERY FROM AC: Yes Yes
THD CURRENT: < 2% < 2%
TYPICAL NIGHTTIME POWER CONSUMPTION: < 7 W < 7 W
AC OUTPUT/ISLANDED
M O D E L
X7602
M O D E L
X11402
MAX. CONT. AC POWER @ 40°C 104°F W/ SINGLE
6 MODULE BATTERY CABINET
1
:
9,000 W 9,000 W
MAX. CONT. AC POWER @ 40°C 104°F
WITH 2 BATTERY CABINETS 8 MODULES MINIMUM:
11,000 W 9,600-11,000 W
2
MAX. CONT. AC POWER @ 50°C 122°F: 8,800 W 7,500-8,800 W
2
PEAK MOTOR STARTING CURRENT 2 SEC: 50 A, RMS
AC BACKUP OUTPUT VOLTAGE: 120/240, 1Ø VAC 120/208, 1Ø VAC
AC FREQUENCY: 60 Hz 60 Hz
THD VOLTAGE: < 2% < 2%
AUTOMATIC SWITCHOVER TIME: < 1 Seconds < 1 Seconds
DC INPUT
M O D E L
X7602
M O D E L
X11402
DC INPUT VOLTAGE RANGE: 360-420 VDC 360-420 VDC
NOMINAL DC BUS VOLTAGE: 380 VDC 380 VDC
DC DISTRIBUTION INPUT BREAKERS: 4 x 2P30 A 4 x 2P30 A
MAX INPUT CURRENT PER DC INPUT: 30 A 30 A
REVERSEPOLARITY PROTECTION: Yes Yes
TRANSFORMERLESS, UNGROUNDED: Yes Yes
TYPICAL NIGHTTIME POWER CONSUMPTION: < 7 W < 7 W
DC BUS EXPORT FUSES +/: 40 A 40 A
2POLE DISCONNECTION: Yes Yes
EFFICIENCY
M O D E L
X7602
M O D E L
X11402
PEAK EFFICIENCY: 97.3% 97.7%
CEC WEIGHTED EFFICIENCY: 96.5% 97.5%
1
Peak Performance
2
In Island mode X11402 protected loads only supply 2 phases 120 VAC L-N, 208 L-L
which results in lower power than in grid tied 3 phase mode. The low value of the
range is for full L-L loading while high value of the range is full L-N loading