Spec Sheet
Generac Mobile Products, LLC l 800-926-9768 l 920-361-4442 l www.generacmobileproducts.com
Page 1 of 4
MLT4060MV
ENGINE SYSTEM
• Mitsubishi® L3E
• Diesel fueled
• EPA Tier 4 Final
• 3 cylinder
• 0.95 L displacement
• Power @ 1,800 rpm – HP (kW):
• Prime: 11.3 (8.4)
• Standby: 12.2 (9.1)
• Air filter: Dry type cartridge
Fuel System
• Tank usable capacity: 56.4 gal (213.5 L)
• Fuel consumption – gph (Lph):
• 100% load: 0.59 (2.2)*
• Fill port diameter: 3.5 in (88.9 mm)
• Fuel filter: replaceable element
Cooling System
• Liquid cooled
Lubrication System
• Oil filter: Full flow, spin-on type
• 1,000-hr service interval**
*Data based on engine manufacturer and field test data after 100-hr engine break-in period. Actual results may vary, according to factors
such as age and maintenance of equipment, environmental conditions, and fuel density. For fuel and maintenance recommendations, see
owner’s manual.
**To achieve maximum service interval, replace oil filter after 50-hr break-in period. See owner’s manual for oil filter model number.
GENERATOR
• 60 Hz engine/generator
• Marathon Electric® brushless
• Up to 6 kW output
• 120/240 VAC, 50/25 A
• ± 6% capacitor voltage regulation
CONTROLS
• Engraved, aluminum punched and anodized control panel
• Key-activated switch with 4 positions (GLOW PLUG, OFF, RUN, START)
• Independent light switches
• Digital hour meter
• Automatic shutdown for low oil pressure and high coolant temperature
SPECIFICATIONS
METAL HALIDE LIGHT TOWER
Picture shown may not reflect actual configuration.