SPECIFICATIONS
MLT4200IF4V
MOBILE LIGHT TOWER
ENGINE CONTROLS (continued)
Shutdown
Engine
o Alarm list – warnings / shutdowns
Over speed protection: shutdown – 115%
• Oil pressure: warning – 25 psi; shutdown – 20 psi
• Coolant temperature: warning – 220°F (104°C); shutdown – 230°F (110°C)
• Battery voltage: over – 15VDC; under – 11VDC
• Generator over voltage: warning – 110%; electrical trip – 111%
• Generator under voltage: warning – 87%; electrical trip – 86%
• Generator over frequency: warning – 105%; electrical trip – 110%
• Generator under frequency: warning – 95%; electrical trip – 90%
ELECTRICAL SYSTEM
• Individual floodlight circuits with 15A breakers
• 100A start limit breaker (assures no load condition exists before starting)
• Standard individually breakered convenience outlets:
o (2) 120 VAC 20 Amp GFCI duplex outlets (NEMA 5-20R type)
o (2) 240 VAC 30 Amp Twistlock outlets (NEMA L6-30R type)
o (2) 240 VAC 50 Amp Twistlock outlets (Non-NEMA 6369)
• 720CCA wet cell battery
FLOODLIGHTS
• (4) light fixtures – 1000 watts each - metal halide
• Oval aluminum reflector
• Tempered glass lens
• Silicone gaskets for moisture and dust protection
• Friction disc mounting for tool less positioning
• Individual floodlight On/Off switches
MAST
• Single toggle switch for raising and lowering vertical mast
• LightTracking System - distinctive angle fixture design for common light distribution
• Mast stowed height: 9.25 ft. (2.82 m)
• 30 ft. (9.14 m) maximum extension, 3-section, tubular steel
• Urethane guides on all sides of mast tubes
• Industrial black powder coat finish
• 1500 lb. (680 kg) automatic self-breaking electric winch – easily raises mast vertically
• 359° ground-level rotation with locking system
• Coiled mast cord
• Equipped with single lifting eye and fork pockets