Product Manual A

General Information
22 Owner’s Manual for MLT6SMD Light Tower
Line Amperage Screen
See Figure 2-12. The Line Amperage screen displays
the AC output amperage produced by the generator in
Amps (A). The load balance for each line (L1 and L3) is
displayed in both numerical and graphical form. It is
important to maintain a balanced load distribution
between lines for optimum generator performance.
Figure 2-10. Line Amperage Screen
Generator Screen
See Figure 2-12. The Generator screen displays the
average line voltage, frequency (in Hertz), and power
factor for the generator while in operation.
Figure 2-11. Generator Screen
Dusk to Dawn Screen
NOTE: This feature will only work in Auto mode.
See Figure 2-12. The Dusk to Dawn screen enables or
disables the “dusk to dawn” function. This function uses a
photo sensor to detect the surrounding light level,
automatically starting the engine and turning the lights on
at dusk. The engine will run and the lights will remain
illuminated until dawn.
For instructions on using the Dusk to Dawn feature, see
Dusk to Dawn Sensor.
Figure 2-12. Dusk to Dawn Screen
Scheduler Screen
NOTE: This feature will only work in Auto mode.
See Figure 2-13. The Scheduler screen enables the
operator to program specific times for the lights to turn on
and off. Once programmed, the Scheduler will start the
engine and illuminate the lights until the designated
shutdown time.
Figure 2-13. Scheduler Screen
002980
002981
002328
002329