28 Owner’s Manual for Mobile Light Tower
Operation
NOTE: The LEDs (A, B, C) allow the operator to monitor
start-up progression. See table below.
6. Begin using lights and receptacles (if equipped), in
accordance with the following:
To operate lights, see Operating Lights—Power
Zone Controls (MANUAL Mode).
To operate 120 V convenience receptacles, see
Customer Convenience Receptacles (If
Equipped).
Starting Unit—Power Zone
Controls (AUTO Mode)
1. See Figure 3-13. Switch controller power to ON (I).
Figure 3-13. Controller Power ON (I)
2. See Figure 3-14. Switch main circuit breaker to
ON (I).
Figure 3-14. Main AC Circuit Breaker ON (I)
3. See Figure 3-15. Press AUTO mode button until
desired schedule is active. See AUTO Run
Scheduling.
NOTE: Due to function of the schedule, the unit might
not start immediately.
AUTO Run Scheduling
AUTO mode requires a schedule for running and shutting
off, which the operator must assign.
See Figure 3-15. Three schedules are available. The
active schedule is indicated by an illuminated LED on the
AUTO mode button.
Figure 3-15. AUTO Mode Button—LEDs
NOTE: The dusk-to-dawn setting (A) utilizes an
adjustable dusk-to-dawn sensor. See Dusk-to-Dawn
Sensor (If Equipped).
A Illuminates when START-STOP button is pushed.
Remains illuminated during start-up process and
while engine is running.
B Flashes when glow plugs are active.
C Illuminates when engine cranks.
010588
010589
MAIN AC
CIRCUIT
BREAKER
A Automatic dusk to dawn.
Engine and lights start and stop in accordance with
ambient brightness at the dusk-to-dawn sensor.
B Schedule 1: Dusk + 8 hours.
Eight-hour engine-run/lighting period, starting at dusk.
Repeats daily.
C Schedule 2: Dusk + 4 hours.
Four-hour engine-run/lighting period, starting at dusk.
Repeats daily.
010583
A
B C