Operation
Shutting Down Unit—Power
Zone Controls (AUTO Mode)
NOTE: In AUTO mode, the unit automatically shuts
down, in accordance with the active schedule.
IMPORTANT NOTE: This procedure cancels AUTO
mode and shuts down the unit.
1. Remove all loads from receptacles. See Remov-
ing Loads from Receptacles (If Equipped).
2. See Figure 3-38. Switch lights OFF (O) by
pressing the light ON-OFF buttons.
Figure 3-28. Light Fixture ON-OFF Buttons
See Figure 3-29. Press AUTO mode button until all
controller LEDs (A, B, and C) are OFF.
Figure 3-29. AUTO Mode Button—LEDs
3. See Figure 3-30. Switch main AC circuit breaker to
OFF (O).
Figure 3-30. Main AC Circuit Breaker OFF (O)
NOTE: See Figure 3-31. Press the engine START-
STOP button once.
Figure 3-31. Engine START-STOP Button
NOTE: Engine begins cool-down cycle, shutting off when
engine is sufficiently cool.
NOTE: To skip cool-down cycle, press the ENGINE
START-STOP button twice.
4. See Figure 3-32. Switch controller power switch to
OFF (O).
Figure 3-32. Controller Power—OFF (O)
Automatic Shutdown
This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system automatically shuts off the fuel supply to stop the
engine if oil pressure drops too low, or the engine
exceeds normal operating temperature. Return the main
circuit breaker to STOP to reset the unit after the cause
of shutdown has been determined.