- Unit Setup
- Raising the Mast—Manual Winch
- Raising the Mast—Electric Winch (If Equipped)
- Prestart Checklist
- Starting Unit—Analog Controls
- Starting Unit—Power Zone Controls (MANUAL Mode)
- Starting Unit—Power Zone Controls (AUTO Mode)
- Operating Lights—Analog Controls
- Operating Lights—Power Zone Controls (MANUAL Mode)
- Operating Lights—Power Zone Controls (AUTO Mode)
- Shutting Down Unit—Analog Controls
- Shutting Down Unit—Power Zone Controls (MANUAL Mode)
- Shutting Down Unit—Power Zone Controls (AUTO Mode)
- Automatic Shutdown
- Starting Utility Mode (If Equipped)—Analog Controls
- Starting Utility Mode (If Equipped—Power Zone Controls
- Stopping Utility Mode (If Equipped)—Analog Controls
- Stopping Utility Mode (If Equipped)—Power Zone Controls
- Dusk-to-Dawn Sensor (If Equipped)
- Customer Convenience Receptacles (If Equipped)
- Removing Loads from Receptacles (If Equipped)
- Storing the Unit
- Lowering the Mast—Manual Winch
- Lowering the Mast—Electric Winch (If Equipped)
- Positive Air Shutdown (PAS) (If Equipped)
- Lower Radiator Hose Heater (If Equipped)
- Tandem Tow (If Equipped)
- Telemetry (If Equipped)
- Spark Arrester (If Equipped)
- Heated Fuel Filter (If Equipped)
- Towing the Unit
- Lifting the Unit
- Tying Down the Unit
- Section 4: Maintenance
- Section 5: Troubleshooting
- Section 6: Wiring Diagrams
32 Owner’s Manual for Mobile Light Tower
Operation
Starting Utility Mode (If
Equipped)—Analog Controls
1. Shut down the unit (if applicable).
2. Open unit hood.
3. See Figure 3-33. Switch the flex switch (if
equipped) to position 0.
Figure 3-33. Flex Switch—Position 0
4. See Figure 3-34. Switch main AC circuit breaker to
OFF (O).
Figure 3-34. Main AC Circuit Breaker OFF (O)
5. See Figure 3-35. Install 240 V, four-terminal cord
to unit power inlet port.
Figure 3-35. Utility Cord Installation to Unit
6. Install 240 V, four-terminal cord to utility power
source.
7. See Figure 3-36. Switch the flex switch (if
equipped) to position 1.
Figure 3-36. Flex Switch—Position 1
8. See Figure 3-37. Switch main circuit breaker to
ON (I).
Figure 3-37. Main AC Circuit Breaker ON (I)
9. See Figure 3-38. Switch lights to ON (I).
Figure 3-38. Lights ON (I)
10. Begin use of the 120 V convenience receptacles.
See Customer Convenience Receptacles (If
Equipped).
11. Close unit hood.
Starting Utility Mode (If
Equipped—Power Zone Controls
1. Shut down the unit (if applicable).
2. Open unit hood.
3. See Figure 3-39. Switch the flex switch (if
equipped) to position 0.
Figure 3-39. Flex Switch—Position 0
4. See Figure 3-40. Switch main AC circuit breaker to
OFF (O).
Figure 3-40. Main AC Circuit Breaker OFF (O)
010595
010587
MAIN AC
CIRCUIT
BREAKER
010597
010598
010589
MAIN AC
CIRCUIT
BREAKER
010590
010595
010587
MAIN AC
CIRCUIT
BREAKER