Product Manual
Table Of Contents
- Section 1: Introduction and Safety
- Section 2: General Information
- Section 3: Operation
- Unit Setup
- Raising the Mast—Manual Winch
- Raising the Mast—Electric Winch (If Equipped)
- Prestart Checklist
- Starting Unit—Analog Controls
- Starting Unit—Power Zone Controls (MANUAL Mode)
- Starting Unit—Power Zone Controls (AUTO Mode)
- Operating Lights—Analog Controls
- Operating Lights—Power Zone Controls (MANUAL Mode)
- Operating Lights—Power Zone Controls (AUTO Mode)
- Shutting Down Unit—Analog Controls
- Shutting Down Unit—Power Zone Controls (MANUAL Mode)
- Shutting Down Unit—Power Zone Controls (AUTO Mode)
- Automatic Shutdown
- Starting Utility Mode (If Equipped)—Analog Controls
- Starting Utility Mode (If Equipped—Power Zone Controls
- Stopping Utility Mode (If Equipped)—Analog Controls
- Stopping Utility Mode (If Equipped)—Power Zone Controls
- Dusk-to-Dawn Sensor (If Equipped)
- Customer Convenience Receptacles (If Equipped)
- Removing Loads from Receptacles (If Equipped)
- Storing the Unit
- Lowering the Mast—Manual Winch
- Lowering the Mast—Electric Winch (If Equipped)
- Positive Air Shutdown (PAS) (If Equipped)
- Lower Radiator Hose Heater (If Equipped)
- Tandem Tow (If Equipped)
- Telemetry (If Equipped)
- Spark Arrester (If Equipped)
- Heated Fuel Filter (If Equipped)
- Towing the Unit
- Lifting the Unit
- Tying Down the Unit
- Section 4: Maintenance
- Section 5: Troubleshooting
- Section 6: Wiring Diagrams
34 Owner’s Manual for Mobile Light Tower
Operation
4. See Figure 3-49. Switch main AC circuit breaker to
OFF (O).
Figure 3-49. Main AC Circuit Breaker OFF (O)
5. See Figure 3-50. Switch the flex switch (if
equipped) to position 0.
Figure 3-50. Flex Switch—Position 0
6. See Figure 3-51. Remove 240 V, four-terminal
cord from unit power inlet port.
Figure 3-51. Utility Cord Removal from Unit
7. Close unit hood.
Stopping Utility Mode (If
Equipped)—Power Zone
Controls
1. Open unit hood.
2. Remove all loads from receptacles. See
Removing Loads from Receptacles (If
Equipped).
3. See Figure 3-52. Switch lights OFF (O) by
pressing the light ON-OFF buttons.
Figure 3-52. Light Fixture ON-OFF Buttons
4. See Figure 3-53. Switch main AC circuit breaker to
OFF (O).
Figure 3-53. Main AC Circuit Breaker OFF (O)
5. See Figure 3-54. On controller, deactivate utility
mode by pushing the Utility Mode button.
Figure 3-54. Utility Mode Button
NOTE: When utility mode is deactivated, the LED (A) is
OFF.
6. See Figure 3-55. Switch controller power to OFF
(O).
Figure 3-55. Controller Power Switch
010587
MAIN AC
CIRCUIT
BREAKER
010595
010599
Light 1
Light 2
Light 4
Light 3
010579
010587
MAIN AC
CIRCUIT
BREAKER
010581
A
010596