Product Manual B
Generac Mobile Products LLC l 800-926-9768 l 920-361-4442 l www.generacmobileproducts.com
Page 2 of 3
SPECIFICATIONS
MTT20IF4
MOBILE COMBO TRAILER
ELECTRICAL SYSTEM CONTROLS
• Individual floodlight circuits with 15A breakers
• Ballast indicator lights
• 100A start limit breaker (assures no load condition exists before starting)
• Standard individually breakered convenience outlets:
o (2) 120 VAC 20 Amp GFCI duplex outlets (NEMA 5-20R type)
o (2) 240 VAC 30 Amp RV style outlets (NEMA TT-30R type)
o (2) 240 VAC 50 Amp twistlock outlets (Non-NEMA 6369)
PUMP
• ShurFLO® pump
o 3.3 gpm (12.5 Lpm) - flow rate
o 3.0 gpm (11.4 Lpm) - flow rate at hose bib
• Hose bib connections include two (2) gravity and two (2) pump
CAPACITIES
• Water tank: 500 gal (1895 L)
• Fuel tank volume: 246 gal (931 L)
• Usable fuel volume: 229 gal (867 L)
• Max run time: 109 hrs
LIGHTING
• Four (4) light fixtures – 1000 watts each - metal halide
• Total lumen output: 440,000
• Coverage: 5-7 acres (20,234 – 28,328 m
2
)
• Coil and core ballast
• Oval aluminum reflector
• Tempered glass lens
• Silicone gaskets for moisture and dust protection
• Individual floodlight On/Off switches
LIGHT TOWER ENCLOSURE
• Steel enclosure – 14-gauge
• UV & fade resistant, high temperature cured, white polyester powder paint
• Stainless steel hinges on doors
• Multi-lingual operating/safety decals
• License plate holder with light
• Manual holder with operating manual