Full Product Manual

EXPLODED VIEW: EV ENCLOSURE C5 EMISSION
DRAWING #: 0J0204
GROUP F
APPLICABLE TO:
ITEM PART# QTY. DESCRIPTION
REVISION: J-8755-G PAGE 2 OF 2
DATE: 5/19/14
(2) 1 0F58730AL0R 1 REAR WRAP C5
(2) 2 0F5868AAL0R 4 DOOR C5
(2) 3 0F5872AAL0R 2 CENTER SUPPORT C5
(2) 4 0F58710AL0R 2 DISCHARGE DUCT LH & RH SIDE C5
(2) 5 0F5869AAL0R 2 FRONT CORNERS C5
(2) 6 0K88730AL0R 1 DUCT CENTER DISCHARGE RAW
(2) 7 0F58670AL0R 1 ROOF C5 ALUM
8 066760 1 STRIP SEALANT 1/8 X 1 (44.5”LG)
9 078115A 12 WASHER SELF LOCKING DOME #8-32
(1)10 0E3257 16 SCREW TH-FRM M6 W/CAP SHKPRF W
(1)11 0C2454 76 SCREW THF M6-1 X 16 N WA Z/JS
12 0F2766 2 SPLITTER
13 0F3181 4 SPLITTER SHORT
14 0F3185 2 STRINGER SPLITTER C3
15 0F3416 2 SUPPORT SPLITTER C5 130KW
16 0J0336 2 INSUL CORNER POST
17 0F4487A 1 ASSY ACCESS COVER
18 022473 5 WASHER FLAT 1/4-M6 ZINC
19 022097 1 WASHER LOCK M6-1/4
20 022127 1 NUT HEX 1/4-20 STEEL
21 0F3072 20 INSULATION RETAINMENT HANGER
22 078115 30 WASHER SELF LOCKING DOME #4-40
23 0J0336B 3 INSUL SPLITTER
24 0J0336A 4 INSUL SHORT LOUVER
25 0F5048D 4 VISE-ACTION LATCH SLOTTED CIR
26 0E5968 1 GASKET EXTRUDED TRIM (566” LG)
27 0F5049B 2 PULL TAB DOOR LOCK SS
28 0J0336G 2 INSUL SPLITTER SML
29 0J2624B 1 INSUL ROOF TOP REAR
30 0F3890A 3 RETAINER INSULATION (740)
31 087233 2 RIVET POP .1875 X .450 SS
32 0J0336C 1 INSUL ROOF TOP FRT
33 0J0336D 4 INSUL DOOR
34 0F3949G 1 INSUL DISCHARGE DUCT
35 0J0336F 2 INSUL CENTER SUPPORT
36 0F3949K 1 INSUL DISCHARGE DUCT TOP
37 0F3949F 2 INSUL INNER DUCT SIDE
38 0F8869D 1 KEY VISE-ACTION LATCH SLOT CIR
39 0F3890 2 RETAINER INSULATION (450)
40 042568 4 SCREW HHC M6-1.0 X 20 G8.8
42 022447 4 WASHER SHAKEPROOF INT 1/4
43 049813 4 NUT HEX M6 X 1.0 G8 YEL CHR
(1) 44 077992 28 NUT HEX LOCK M6-1.0 SS NY INS
45 0912970090 4 ASSY WIRE 14AWG GRN/YEL
46 0F2766A 1 SPLITTER C5
47 0J0336H 1 INSUL SPLITTER SHRT MPS
(1)ENCLOSURE NOTE: ALL PANELS THAT FASTEN TO THE BASEFRAME MUST BE SECURED USING I/N 10 & 11 (THREAD FORMING FASTENERS) AND I/N
44 (LOCK NUT). LOCK NUT IS TO BE INSTALLED AFTER THREAD FORMING FASTENER HAS PENETRATED THROUGH EXTRUSIONS IN ENCLOSURE
PANELS. ALL PANEL TO PANEL CONNECTIONS TO INCLUDE AT LEAST ONE CONNECTION POINT USING I/N 10 (THREAD FORMING FASTENER).
(2) SHEET METAL PARTS LISTED IN THE BOM TABLE ARE REPRESENTING GENERIC PARTS (NO COLOR)
MANUFACTURING: FOR CORRECT MATERIAL AND COLOR REFER TO AS400 BOM.
CUSTOMER: WHEN ORDERING REPLACEMENT PARTS ENTER BASE NUMBER (FIRST 6 DIGITS ONLY) IN THE SYSTEM FOR CORRECT
MATERIAL AND COLOR (FOR REFERENCE SEE GUIDELINE 0H7169).