PV Array AC Grid Power Conversion PWRcellTM Inverter PV Optimization PV LinkTM Substring Optimizer REbusTM DC nanogrid 30A M Generac PowerCore CTs (CAT5) 30A 30A 30A 100A 50A Ethernet (CAT5) 40A 60A Main Service Panel Router Storage PWRcell Battery Loads Panel Powered by REbus (DC Voltage) AC Voltage FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance. *Refer to product manuals for additional installation details and requirements.
Powered by REbus (DC Voltage) AC Voltage FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance. *Refer to product manuals for additional installation details and requirements. This design shows a PWRcell system with a Protected Loads panel to provide backup power to loads. Utilize this design where roof installation for PV is not possible (e.g. condos, rented spaces). There are DC inputs available for additional battery storage or to add PV in the future.
AC Grid PV Array Power Conversion PWRcellTM Inverter PV Optimization PV LinkTM Substring Optimizer REbusTM DC nanogrid 30A Generac PowerCore M CT (CAT5) 30A 30A 30A Ethernet (CAT5) 50A N 40A E Router NOTE: In this configuration, the generator does not charge PWRcell batteries or parallel with the inverter.
PV Array AC Grid Power Conversion PWRcellTM Inverter PV Optimization PV LinkTM Substring Optimizer REbusTM DC nanogrid 30A M Generac PowerCore CTs (CAT5) 30A 30A 30A 40A RGM ATS (CAT5) Main Distribution Panel ATS Kit Ethernet (CAT5) Router Powered by REbus (DC Voltage) AC Voltage 200A 50A Storage PWRcell Battery N E L Automatic Transfer Switch GeneracĀ® RXS FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance.
AC Grid PV Array PV Optimization PV LinkTM Substring Optimizer Power Conversion PWRcellTM Inverter Generac PowerCore 30A M 30A 30A 30A 50A CNTRL CTs TRANS N Ethernet E PWRcell ATS T Router Powered by REbus (DC Nanogrid) AC Wiring DC Wiring (excluding REbus) CAT5 Comms Wiring Control Wiring TM Load Load Storage PWRcell Battery SMM SMM SMM Load FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance.
PV Array AC Grid Power Conversion PWRcellTM Inverter PV Optimization PV LinkTM Substring Optimizer REbusTM DC nanogrid 30A M Generac PowerCore CTs (CAT5) 30A 30A 30A 200A Ethernet (CAT5) 50A Router 40A Main Distribution Panel Storage PWRcell Battery Powered by REbus (DC Voltage) AC Voltage FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance. *Refer to product manuals for additional installation details and requirements.
AC Grid PV Array PV Optimization PV LinkTM Substring Optimizer Power Conversion PWRcellTM Inverter Generac PowerCore 30A M 30A 30A 30A 50A CNTRL CTs TRANS N Ethernet E PWRcell ATS T Router Powered by REbus (DC Nanogrid) AC Wiring DC Wiring (excluding REbus) CAT5 Comms Wiring Control Wiring TM Storage PWRcell Battery 40A FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance. *Refer to product manuals for additional installation details and requirements.
AC Grid RS RS RS PV Optimization PV LinkTM Substring Optimizer Power Conversion PWRcellTM Inverter 400A 400 A Meter-Main Combo Service Panel 200A RS RS 30A RS 200A Generac PowerCore Generac PowerCore 30A 30A 30A 30A 50A 50A CNTRL CTs TRANS N Ethernet E 200 A 200 A PWRcell PWRcell ATS ATS RS FOR REFERENCE ONLY; NOT FOR CONSTRUCTION. *Installer responsible for code compliance. *Refer to product manuals for additional installation details and requirements.