Install Instructions
General Filters
Incorporated
27 | P a g e
10.5 Housing Knockouts
Determine if the steam will be entering the housing from the back or bottom. Remove the knockouts for the steam
hose, condensate hose and electrical connections. (See Figure 10.d.).
.
10.6 Installation
Insert RMB housing into the wall and bend the four securing tabs around the back of the drywall. Level the RMB, then
secure the RMB housing to the wall using predrilled holes (Figure 6.1) located on the four one-inch flanges of the RMB
unit. Use #8 drywall screws (four required) to penetrate the drywall and pass through the slot in the securing tab
behind the drywall (See Figure 10.e and 10.f). An alternate installation method is to frame out the opening of the RMB
to the dimensions shown in Figure 10.c.
NOTE:
1. The four one-inch flanges on the face of the RMB unit must be on the outside of the drywall. Failure to
locate the flanges on the outside face of the drywall may result in water leakage and household
damage.
5 – 11/16”
Figure 10.d.
TERMINAL BLOCK