User's Manual Part 2

Node B Rack Mount Installation Guide
Version 0.0.3 Page 22 of 39
Precautions
The following precautions and checks are applicable to all mounting types:-

Connectors have been manufactured to fit their specific cables and funcition. Do not
modify or force connectors.

Check Site Plans for engineering approval.

Ensure that good ground resistance is available at the installation site (10)

Where installed in an outdoor enclosure attention should be paid to cooling and
water+dust sealing prevention refer to Table 5-1.
Rack Mounting – Installing Digital Shelf
Ensure the shelf or shelf supports are secure, then insert the digital shelf into the rack and
secure from the front.
Notes:

If there is no rear access it may be required to make the ground connection prior to
inserting the shelf into the rack.

Where additional securing is required at the rear this shall require custom brackets
depending on the rack specifications/construction.
Figure 6-7: Installing Digital Shelf