User's Manual

Table Of Contents
Fortress ES-Series CLI Guide: Networking and Radio Configuration
70
3.4.11 ES210 Mesh Point STA Settings and
Operation
NOTE:
Each Mesh
Point radio can
alternatively support up
to four
BSS
interfaces.
Refer to Section 3.4.9.
Configuring a station (sta or STA) interface on the ES210
Mesh Point radio causes the Mesh Point to act as a dedicated
WLAN client device, or station, rather than as an AP or a
wireless bridge (or FastPath Mesh Point).
An ES210 configured with such an interface is in station mode.
Only a single STA Interface is permitted on a given ES210, and
when one is present, no additional wireless interface of any
type can be configured. If one or more BSSs have been
configured on the Mesh Point radio, you must delete all BSSs
before you can enable a STA interface.
NOTE:
On the
ES210, the port
Ethernet1 is labeled
Ethernet (WAN) on the
chassis, and Ethernet2 is
labeled Ethernet.
Station mode is supported only by the ES210 Mesh Point.
A STA
interface can only bridge between a wireless network
AP and one or more Ethernet devices connected to the clear
Ethernet port(s) on the ES210. In addition, no wired (Ethernet)
bridging can occur when the Mesh Point is in station mode. An
ES210 in STA mode does not support Fast Path Mesh bridging
(Section 3.2.2), but can function, like other wireless devices, as
an NMP (non-Mesh Point) on a FastPath Mesh Network. In
other words, an ES210 in STA mode should be configured to
run STP bridging mode rather than MESH bridging mode.
For example, on an ES210 on which the Ethernet2 port is clear
and the Ethernet1 port is encrypted (the defaults), a typical
station mode setup would use the Ethernet2 port to connect
one or more Ethernet devices. If the Ethernet1 port is in the
clear zone, it can be used in the same way. Devices on a clear
Ethernet port, however, cannot communicate with devices on
an encrypted Ethernet port when the ES210 is in station mode.
You can preconfigure a STA interface with the settings required
to connect to a specific network. Alternatively, you can scan for
available networks within range and select one to use to create
the
sta interface that will connect the ES210 to the network.
In order to facilitate the ES210 Mesh Point's Station Mode
network scanning function, a temporary STA interface,
__FORTRESS__TEMP_STA__, is present in the default
configuration. This STA Interface must be enabled in the GUI
before it will be visible in the CLI (see the Fortress Mesh Point
Software GUI Guide). View the default station configuration
with
show sta:
# show sta
RadioName: radio1
Name: __FORTRESS__TEMP_STA__
Ssid: __FORTRESS__TEMP_STA__
Bssid: 00:00:00:00:00:00
AdminState: enable