Table 3-3. Remote Transceiver Operation Commands (Cont)
CODE NAME DESCRIPTION
EQUIVALENT
TRANSCEIVER
KEYPAD COMMAND
+ Keypad Control When in the Remote Mode, the “+” Command
remotely re-enables the keypad.
6
MODE
R/T
(See Paragraph 2-3.3.4)
B Transmit Command The “B” Command sets the transceiver into the
transmit mode from the receive mode.
Note, to set the transceiver back to the receive
mode, use the "E" Command as described
below.
None)
E Receive Mode The “E” Command returns the transceiver from
the transmit mode back to the receive mode.
Note, to set the transceiver into the transmit
mode, use the "B" Command as described
above.
None)
The following command applies to transceivers with the EBN-30 Option, 30-90 MHz Band Enhancement
>
Note 1
150 Hz Tone Squelch This command is only effective for 30 - 90 MHz
range frequencies.
Transceivers with the EBN-30 Option, for the
30-90 MHz band, the “>” Command followed
by a 0, 1, 2, or 3 will enable/disable the 150
tone squelch.
“>0” = Turns OFF the 150 Hz tone squelch for
both receive and transmit.
“>1” = Turns ON the 150 Hz tone squelch for
receive only.
“>2” = Turns ON the 150 Hz tone squelch for
transmit only.
“>3” = Turns ON the 150 Hz tone squelch for
both receive and transmit.
Transceivers with the UPL-100 Option, Private
Line (PL), will note that if the Private Line tone
is currently ON, the “>” Command will return a
"NAK".
CH/BW
2
TONE