Operation Manual

Technical and optical design modifications are subject to change without notice
Picture 2: electronic control
LED LED LED LED button button UP+ button DOWN+ button
alarm evaporator com- ECO SET manual horn off info
ventilating fan pressor defrost
LED button button
defrost ECO on / off
Survey of buttons and operation of electronic control
To switch device on / off press button for approx. 2 seconds
Pressing this button leads to menu "INFO", button "SET" gives access
to ask for the following formations
T 1 = temperature room probe
T2 = temperature evaporator probe
Thi = maximum temperature (HACCP)
Tlo = minimum temperature (HACCP)
CND = period of operation since last cleaning of condenser
LOC = button lock
During display of values Thi, Tio and CND these may be put back to
0 by pressing in addition the info button
Pressing this button for approx. 3 sec. starts a manual defrost.
During each defrosting process display shows "DEF" and the LED
defrost lights.
Should the display show one of the following alarms, a hoorn sounds
at the same time which may be switched off by pressing this button
for 3 sec.
HI = temperature 10°C beyond set rated value
Ho = temperature 10°C less than set rated value
Do = door open for more than 2 minutes
HP = high pressure compressor (devices with built-in
refrigeration machine only)
E1 = probe T1 defective
E2 = probe T2 defective