Installation Instructions
STEP 19: PRETEST CHECKLIST
Review this list after installing your dishwasher to avoid 
charges for a service call that is not covered by your 
warranty.
• Check to be sure power is OFF.
• Open door and remove all foam and paper packaging.
• Locate the Owner’s Manual set aside in Step 1.
• Read the Owner’s Manual for operating instructions.
• Check door opening and closing. If door does not open and 
close freely, check for proper routing of spring cable over 
SXOOH\,IGRRUGURSVRUFORVHVZKHQUHOHDVHGDGMXVWVSULQJ
tension. See Step 2.
• Check to be sure that wiring is secure under the dishwasher, 
not pinched or in contact with door springs or other 
components. See Step 18.
• Check door alignment with tub. If door hits tub, level 
dishwasher. See Step 14.
• Check door alignment with cabinet. If door hits cabinet, 
reposition dishwasher. See Step 13.
• Check that door spring does not contact water line, fill hose, 
wiring or other components. See Step 13.
• Verify water supply and drain lines are not kinked or in 
contact with other components. Contact with motor or 
dishwasher frame could cause noise. 
• Turn on the sink hot water faucet and verify water 
temperature. Incoming water temperature must be between 
120°F and 140°F. A minimum of 120°F temperature is 
required for best wash performance. See “Prepare Hot Water 
Line,” page 5.
• Add 1 quart of water to the bottom of the dishwasher to 
lubricate the pump seal.
• Turn on water supply. Check for leaks. Tighten connections if 
needed.
• Remove protective film if present from the control panel and 
door.
• Check that tub trim does not contact the door.
Dishwasher Installation
13
STEP 18: CONNECT POWER SUPPLY
If a power cord with plug is already installed proceed to 
Step 19. 
,QWKLVVWHS\RXZLOOQHHGWKHMXQFWLRQER[FRYHUDQGWKH 
#10 Hex head screw from the screws set aside in Step 1.
6HFXUHKRXVHZLULQJWRWKHEDFNRIWKHMXQFWLRQER[ZLWKD
strain relief.
• Locate the 3 dishwasher wires, (white, black and green) with 
WKHVWULSSHGHQGVFRPLQJRXWRIWKH$&MXPSHU8VH8/OLVWHG
wire nuts of appropriate size to connect incoming ground to 
green, white to white and black to black.
,QVWDOOWKHMXQFWLRQER[FRYHUXVLQJKH[KHDGVFUHZ
Check to be sure that wires are not pinched under the cover.
0DNHVXUHWKDWWKHMXQFWLRQER[FRYHULVUHVWLQJRQWKH
mounting bracket.
• If using a Power Cord Kit, use GE part number WX09X70910 
or WX09X70911 and refer to the included instructions.
If house wiring is not 2-wire with ground, a ground must be 
provided by the installer. When house wiring is aluminum, be sure 
to use UL-Listed anti-oxidant compound and aluminum-to-copper 
connectors.
Figure AD
Ground 
(Green)
NOTE: Do not remove the 
Junction Box Bracket.
AC 
Jumper
Junction Box 
Bracket
Black
White
Ground Screws
NOTE: All ground screws, brackets and wires must remain 
intact.
 WARNING