MOBILE OR MANUFACTURED 
HOME INSTALLATION
•  Installation MUST conform to the 
MANUFACTURED HOME CONSTRUCTION 
AND SAFETY STANDARD, TITLE 24, PART 
3280 or STANDARD FOR MOBILE HOMES 
CAN/CSA-Z240 MH, or, when such standards 
are not applicable, with AMERICAN NATIONAL 
STANDARD FOR MOBILE HOME, ANSI/NFPA 
NO. 501B.
•  The dryer MUST be vented to the outdoors.
•  The exhaust vent MUST be securely fastened to a 
non-combustible portion of the mobile home.
•  The vent MUST NOT be terminated beneath a 
mobile or manufactured home.
•  The vent duct material MUST BE METAL.
•  KIT 14-D346-33 MUST be used to attach the dryer 
securely to the structure.
•  The vent MUST NOT be connected to any other 
duct, vent or chimney.
•  DO NOT use sheet metal screws or other 
fastening devices which extend into the interior of 
the exhaust vent.
•  Provide an opening with a free area of at least 25 
square inches (63 cm
2
) for introduction of outside 
air into the dryer room.
•  See the sections for electrical connection information. 
REQUIREMENTS FOR ALCOVE OR 
CLOSET INSTALLATION
Keep flammable materials and vapors, such as gasoline, 
away from dryer.
Place dryer at least 18” (46 cm) above the floor for a 
garage installation.
Failure to do so can result in death, explosion, or fire.
•  The dryer MUST be vented to the outdoors. 
•  Minimum clearance between dryer cabinet and 
adjacent walls or other surfaces is:
      0” (0 cm) either side
*
      0” (0 cm) front
      0” (0 cm) rear
   0” 
(0 cm) 
top
* For improved performance, a 1/2” (12.7 mm) 
clearance is suggested on each side.
•  The rear of the dryer should face a wall.
•  Consideration must be given to provide adequate 
clearance for installation and service.
•  Closet doors must be louvered or otherwise 
ventilated and have at least 60 square inches (387 
cm
2
) of open area. If the closet contains both a 
washer and a dryer, doors must contain a minimum 
of 120 square inches (774 cm
2
) of open area.
NOTE: WHEN THE EXHAUST DUCT IS LOCATED AT 
THE REAR OF THE DRYER, THE CONFIGURATION 
OF THE DUCTING MAY REQUIRE GREATER 
CLEARANCE.
Gas Dryers Only:
•  No other fuel burning appliance shall be installed in 
the same closet as a gas dryer.
•  The dryer must be disconnected from the gas 
supply piping during pressure testing at pressures 
greater than 1/2 psi (3.5 kPa).
•  A 1/8” (3.2 mm) NPT minimum plugged tapping, 
accessible for test gauge connection, must be 
installed immediately upstream of the gas supply 
connection to the dryer.
MINIMUM CLEARANCE OTHER 
THAN ALCOVE OR CLOSET 
INSTALLATION
Minimum clearance to combustible surfaces and for 
air opening are: 0” (0 cm) both sides*, 0” (0 cm) rear 
and 0” (0 cm) top.
* For improved performance, a 1/2” (12.7 mm) 
clearance is suggested on each side.
The rear of the dryer should face a wall.
Consideration must be given to provide adequate 
clearance for installation and service.
- Explosion Hazard