Use and Care Guide
49-3000206 Rev 5 17
Installation Instructions
CONNECTING INLET HOSES (for steam dryer models only)
CONNECTING INLET HOSES (cont.)
7. Using pliers, tighten all the couplings with an 
additional two–thirds turn.
NOTE: Do not overtighten. Damage to the 
couplings may result.
8. Turn the water faucet on.
9. Check for leaks around the ‘’Y’’ connector, 
faucet and hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets MUST be installed 
within 42 in. (107 cm) of your washer’s water 
inlet. The faucets MUST be 3/4” (19.1 mm) 
garden hose-type so inlet hoses can be 
connected. Water pressure MUST be between 
10 and 120 pounds per square inch. Your 
water department can advise you of your water 
pressure.
NOTE: A water softener is recommended 
to reduce buildup of scale inside the steam 
generator if the home water supply is very hard.
To produce steam, the dryer must connect to 
the cold water supply. Since the washer must 
also connect to the cold water, a “Y” connector 
is inserted to allow both inlet hoses to make that 
connection at the same time.
NOTE:  Use new inlet hoses; never use old 
hoses.
1. Turn the cold water faucet off. Remove the 
washer inlet hose from the washer fill valve 
connector (cold).
2. Ensure the rubber flat washer is in place and 
attach one female coupling of the short hose 
provided onto the washer fill valve connector. 
Tighten by hand until firmly seated.
3. Attach one male end of the “Y” connector to 
the other female coupling of the short hose. 
Ensure the rubber flat washer is in place. 
Tighten by hand until firmly seated.
4. Insert the filter screen in the coupling of the 
washer’s inlet hose. If a rubber flat washer is 
already in place remove it before installing the 
filter screen. Attach this coupling to one male 
end of the ‘’Y’’ connector. Tighten by hand until 
firmly seated.
5. Ensure the rubber flat washer is in place 
and attach a 4 ft. (1.2 m) to 6 ft. (1.8 m) long 
water inlet hose (may need to be purchased 
separately) to one male end of the ‘’Y’’ 
connector. Tighten by hand until firmly seated.
6. Ensure the rubber flat washer is in place and 
attach the other end of the dryer’s long inlet 
hose to the fill valve connector at the bottom 
of the dryer back panel. Tighten by hand until 
firmly seated.
CONNECTING INLET HOSES