Installation Instructions
GAS REQUIREMENTS
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
•  A 1/8” (3.2 mm) National Pipe Taper thread 
plugged tapping, accessible for test gauge 
connection, must be installed immediately 
upstream of the gas supply connection to the 
dryer. Contact your local gas utility should you 
have questions on the installation of the plugged 
tapping.
•  Supply line is to be 1/2” (12.7 mm) rigid pipe and 
equipped with an accessible shutoff within 6 feet 
(1.8 m) of, and in the same room with, the dryer.
•  Use pipe thread compound appropriate for 
natural or LP gas or use PTFE tape.
•  Connect flexible metal connector to dryer and 
gas supply.
ADJUSTING FOR ELEVATION
• Gas clothes dryers input ratings are based on 
sea level operation and need not be adjusted for 
operation at or below 2000 ft. (610 m) elevation. 
For operation at elevations above 2000 ft. (610 m), 
input ratings should be reduced at a rate of 4 
percent for each 1000 ft. (305 m) above sea level. 
• Installation must conform to local codes and 
ordinances or, in their absence, the NATIONAL 
FUEL GAS CODE, ANSI Z223.
You must use with this dryer a flexible metal connector 
(listed connector ANSI Z21.24 / CSA 6.10). The length 
of the connect shall not exceed 4 ft. (1.2 m).
• Use a new CSA International approved flexible 
gas supply line. Never reuse old flexible 
connectors.
• Install an individual manual shut-off valve 
within 6ft. of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 
54.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified 
person make sure gas pressure DOES NOT 
exceed 13” (33 cm) water column.
• Examples of a qualified person include: 
licensed heating personnel, authorized gas 
company personnel, and authorized service 
personnel.
• Failure to do so can result in death, 
explosion, or fire.
•  The installation must conform with local 
codes, or in the absence of local codes, with 
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the Natural Gas and Propane 
Installation Code, CSA B149.1.
FOR USE WITH NATURAL GAS ONLY
Dryer as produced by manufacturer is to be used 
only with a natural gas supply. A manufacturer-
supplied conversion kit is required to convert this 
dryer for propane gas supply. Use propane 
gas 
conversion kit WE25M87
. Conversion must be 
made by properly trained and qualified personnel 
in accordance with local codes and ordinances.
- Fire Hazard
WARNING
- Explosion Hazard
WARNING
CONNECTING A GAS DRYER (cont.)
NOTE: Add to vertical dimension the 
GLVWDQFHEHWZHHQFDELQHWERWWRPWRÀRRU
3/8” (9.6 mm) NPT 
MALE THREAD 
GAS SUPPLY
1-5/8” (4.16 cm)
5-3/4” 