Use and Care Guide
20 49-3000206 Rev 5
Installation Instructions
CONNECTING A GAS DRYER (cont.)
 Install a 1/8” (3.2 mm) NPT plugged tapping 
to the dryer gas line shut-off valve for 
checking gas inlet pressure.
 Install a flare union adapter to the plugged 
tapping.
 NOTE: Apply pipe compound or PTFE tape 
to the threads of the adapter and plugged 
tapping.
 Attach the flexible metal gas line connector to 
the adapter.
B
 Tighten the flexible gas line connection, using 
two adjustable wrenches.
C
D
 Tighten all connections, using two adjustable 
wrenches. Do not overtighten.
E
CONNECTING THE DRYER TO 
THE GAS SUPPLY (cont.)
 Open the gas shut-off valve.
F
Apply pipe compound 
or PTFE tape to all 
male threads.
Shut-Off 
Valve
Plugged 
Tapping
CONNECTING THE DRYER TO 
THE GAS SUPPLY
 Install a female 3/8” (9.6 mm) NPT elbow at 
the end of the dryer gas inlet.
 Install a 3/8” (9.6 mm) flare union adapter to 
the female elbow.
  IMPORTANT: Use a pipe wrench to securely 
hold on to the end of the dryer gas inlet to 
prevent twisting the inlet.
 NOTE: Apply pipe compound or PTFE tape to 
the threads of the adapter and dryer gas inlet.
A
Elbow
Adapter
Items not supplied
Adapter
1/8” (3.2 mm) 
NPT Pipe Plug 
for Checking 
Gas Inlet 
Pressure
Shut-Off Valve
Pipe size at 
least 1/2” (12.7 
mm)
3/8” (9.6 mm) 
NPT
New Metal 
Flexible Gas 
Line Connector
Apply pipe compound to the 
adapter and dryer gas inlet.