Use and Care Guide
49-3000206 Rev 5 25
Installation Instructions
EXHAUSTING THE DRYER
CONNECTING THE DRYER TO 
HOUSE VENT
RIGID METAL TRANSITION DUCT
•  For best drying performance, a rigid metal transition 
duct is recommended.
•  Rigid metal transition ducts reduce the risk of 
crushing and kinking.
UL-LISTED FLEXIBLE METAL CLOTHES 
DRYER TRANSITION DUCT
• If rigid metal cannot be used, then UL-listed flexible 
metal clothes dryer transition duct (GE Appliances 
part – PM08X10085) can be used.
•  Never install transition duct in walls, ceilings, floors 
or other enclosed spaces.
•  Total length of transition duct should not exceed 8’ 
(2.4 m).
•  For many applications, installing elbows at both 
the dryer and the wall is highly recommended (see 
illustrations in next section). Elbows allow the dryer 
to sit close to the wall without kinking and/or crushing 
the transition duct, maximizing drying performance.
•  Avoid resting the duct on sharp objects.
UL-LISTED FLEXIBLE METAL (FOIL-TYPE) 
TRANSITION DUCT
• In special installations, it may be necessary to 
connect the dryer to the home exhaust vent 
using flexible metal (foil-type) transition duct. UL–
LISTED universal flexible dryer transition duct 
(GE Appliances parts – PM8X73 or WX8X73) 
may be used ONLY in installations where rigid 
metal or flexible metal transition ducting cannot 
be used AND where a 4” (10.2 cm) diameter can 
be maintained throughout the entire length of the 
transition duct.
•  In Canada and the United States, only transition 
ducts that comply with “UL 2158A STANDARD 
FOR CLOTHES DRYER TRANSITION DUCT” 
shall be used.
•  Avoid resting the duct on sharp objects.
•  For best drying performance:
 1.  Slide one end of the duct over the clothes 
dryer outlet pipe.
 2.  Secure the duct with a clamp.
 3.  With the dryer in its permanent position, 
extend the duct to its full length. Allow 2” (5.08 
cm) of duct to overlap the exhaust pipe. Cut 
off and remove excess duct. Keep the duct as 
straight as possible for maximum airflow.
 4.  Secure the duct to the exhaust pipe with the 
other clamp.
This dryer MUST be vented to the outdoors.
Use only 4” (10.2 cm) rigid metal ducting for 
the home exhaust duct.
Use only 4" (10.2 cm) rigid metal, UL-listed 
flexible metal, or UL-listed metal foil dryer 
transition duct to connect the dryer to the 
home exhaust.
DO NOT use any plastic to vent the dryer, 
this includes the home exhaust duct, dryer 
transition duct, or within the dryer.
DO NOT use flexible metal or metal foil ducting 
for a home exhaust duct or within the dryer.
DO NOT exhaust into a chimney, kitchen 
exhaust, gas vent, wall, ceiling, attic, crawl 
space, or concealed space of a building.
DO NOT install a screen in or over the exhaust 
duct.
DO NOT install a booster fan in the exhaust duct.
DO NOT use duct longer than specified in the 
exhaust length table.
Failure to follow these instructions can result in 
death or fire.
PARTS AVAILABLE FROM 
GEAPPLIANCEPARTS.COM OR 
LOCAL SERVICE ORGANIZATIONS
GFA28DSVN
(WE16X29317)
Dryer Venting Kit
PM8X85
Outdoor exhaust hood
WX08X10130   4” (10.2 cm) Dryer exhaust clamp
- Fire Hazard
WARNING
TOOLS AND MATERIALS YOU WILL 
NEED TO INSTALL EXHAUST DUCT
Ŷ
Ŷ
 1/4" (6.4 mm) Socket & 
Nut Driver
Ŷ
Ŷ
 1/4" (6.4 mm) Socket & 
Wrench
Ŷ
Ŷ
 Vent hood
Ŷ
Ŷ
 Duct tape or 
duct clamp