First reset the current settings to Factory Settings on the counter:
Scroll to 3-DSPLAY
Skip through the parameters until FACT SET is displayed.
Change this to YES by pressing RST
PRO NO should be displayed, Press SEL.
Continue to re-program the Counter by pressing and holding SEL to re-enter
programming mode. Pro-no will be displayed, press RST to move through the relevant
sections. The following parameters are required for the Tornado counter:
Press RST Once:
Counter Parameters (1-INPUT)
INPA-B = Cnt ud - if correct press SEL.
CNT A DP = 0 - if correct press SEL.
CNT A SCF = 0.01 (Metric, m) or 0.0328 (Imperial, ft) - once
correct press & Hold SEL.
CNT A RST = TO ZERO - if correct press SEL.
CNT A DIR = NOR - if correct press SEL.
CNT B LD = 0 - once correct press & Hold SEL.
CNT B BAT = NO - if correct press SEL.
RST P-UP = NO - if correct press SEL.
USER INP = NO - if correct press SEL.
Press RST Twice:
Rate Parameters (2-RATE)
RATE ENB = YES - if correct press SEL.
RATE DP = 0 - if correct press SEL.
RATE DSP = 60 - once correct press & Hold SEL.
RATE INP = 100 (Metric, m/min) or 30.5 (Imperial, ft/min)-
once correct press & Hold SEL.
LO-UDT = 1.0 - if correct press SEL.
HI-UDT = 2.0 - if correct press SEL.
Press RST Three times:
DISPLAY (3-DSPLAY)
SEL ENB = YES - if correct press SEL.
RST ENB = YES - if correct press SEL.
D-SCROLL = NO - if correct press SEL.
PRO CODE = 222 - CODE REQUIRED TO RE-PROGRAM -
once correct press & Hold SEL.
FACT SET = NO - Press SEL Twice