Owner's manual

Page 34 of 40
General Machine Products Co., Inc.
Counter programming parameters for the Duct Rod Pusher
Scroll to 3-DSPLAY
Skip through the parameters until FACT SET is displayed. Change this to YES by pressing RST
PRO NO should be displayed, Press SEL.
Continue to re-program the Counter by pressing and holding SEL to re-enter programming
mode. Pro-no will be displayed, press RST to move through the relevant sections. The following
parameters are required for the counter:
Press RST Once:
Counter Parameters (1-INPUT)
INPA-B = QUAD 4 – if correct press SEL.
CNT A DP = 0.00 (for metric metres) or 0.0 (for imperial feet) - if correct press SEL.
CNT A SCF = 00.4167 (for metric, m) or 00.1353 (for feet)– once correct press & Hold SEL.
CNT A RST = TO ZERO - if correct press SEL.
CNT A DIR = NOR - if correct press SEL.
CNT A LD = 0 – once correct press & Hold SEL.
CNT B BAT = NO - if correct press SEL.
RST P-UP = NO - if correct press SEL.
USER INP = NO - if correct press SEL.
Press RST Twice:
Rate Parameters (2-RATE)
RATE ENB = YES - if correct press SEL.
RATE DP = 0 - if correct press SEL.
RATE DSP = 60 - once correct press & Hold SEL.
RATE INP = 60 (Metric, m/min) or 18 (Imperial, ft/min) – once correct press & Hold SEL.
LO-UDT = 1.0 - if correct press SEL.
HI-UDT = 2.0 - if correct press SEL.
Press RST Three times:
DISPLAY (3-DSPLAY)
SEL ENB = YES - if correct press SEL.
RST ENB = YES - if correct press SEL.
D-SCROLL = NO - if correct press SEL.
PRO CODE = 222 – CODE REQUIRED TO RE-PROGRAM - once correct press & Hold SEL.
CODE VER = NO - if correct press SEL.
FACT SET = NO – Press SEL Twice