Manual

Page 10 of 44
4.0 SPECIFICATION
* The sensitive electronics needed to give the desired control over the installation speed and torque
require a certain electrical supply quality. Should a generator be necessary General Machine
recommends the use of an inverter type generator with a pure sine wave output. Please contact
General Machine Products Co., Inc. should you require further assistance.
Cable size: 2.5 to 11.0mm 0.118” to 0.433
Tube size: (OD) 5 to 18.0mm 0.197” to 0.708
Cable speed: 0-80m/min. 0-262 ft/min
Maximum pushing force: 20 Kg. 44 lb.
Maximum air pressure: 15 bar. 210 psi.
Power requirements:*
100-277Vac 50/60 Hz
(power supply input)
48Vdc, 250W
(power supply output)
Weight 14Kg approx. 31 lbs. approx.
Weight inc case 31 Kg approx. 68 lbs. approx.
Dimensions (ht x length x width) 266mmx460mmx305mm 10 1/2”x18 1/8” x12”
Ambient Temperature Range 0-40° C 32-104° F