41H = Subfunction ID = PARAMETER DATA
00 = Model ID, 00 = WK4
cf = checksum=1, format (5 per Status, 0 altrimenti)
pp = packet number (00:7fH)
<data>
cc = checksum
F7H = EOX
The data sent refer to the structure as described below.
Status Data. The data relates to the parameters contained in the following fields (the quantities of memory are expressed in
Kbyte):
bytes rel.addr. name description
1 0 iClass see classification in Tab.1
1 1 iSubClass see classification in Tab.1
1 2 iRelease instrument release
1 3 peripherals HD=b1, AV=b0
4 4 totalSysRam Total System Memory
4 8 freeSysRam Freee System memory
4 12 totalBackedRam Backed Sample Ram Memory
4 16 freeBackedRam Free Backed Sample Ram Memory
4 20 totalVolRam Total Volatile Sample Ram Memory
4 24 freeVolRam Free Volatile Sample Ram Memory
iClass / iSubClass 12345678
1 - Synth Expander S2 S3 S2 Box SK76 SK88
2 - Masterkeyboards MK88
3 - Keyboards WS2 WS1 WX2 WX2Box CD WX400 WK4 SX2 SX3 WK3
4 - Pianos WS400 RPro1 RPro2 RPprox Ps2500 PS1500
5 - Home Organs
6 - Classic Organs
7 - Accessories AS-1
(TAB.1)
Parameter Data. In this case the streams relating to the parameter names requested are returned and all the data is identifed
by the following 16 bytes:
0 1 2 3-15
Parameter ID Bank Select Perf Select Parameter Name (13 char Max)
The parameters bs (bank select) and ps (prChange select) contained in the request vary according to the parameter as in
Tab.2, taking into accound that the request will have effectively followed only in the case in which what has been requested is
actually present in the system; to be able to request all the values available for a given parameter, it is sufficient to send the values
bs=00 e ps=00.
STATUS SOUND REAL PERF. STYLE SONG
Bank Select Range 00 1 - 16 1 - 8 1 - 96 1 - 16
PrCh Select Range 00 1 - 128 not used (nu) nu nu
(Tab.2)
41H = Subfunction ID = PARAMETER DATA
00 = Model ID, 00 = WK4
cf = checksum=1, format (5 per Status, 0 altrimenti)
pp = packet number (00:7fH)
<data>
cc = checksum
F7H = EOX
The data sent refer to the structure as described below.
Status Data. The data relates to the parameters contained in the following fields (the quantities of memory are expressed in
Kbyte):
bytes rel.addr. name description
1 0 iClass see classification in Tab.1
1 1 iSubClass see classification in Tab.1
1 2 iReleaseinstrument release
1 3 peripherals HD=b1, AV=b0
4 4 totalSysRam Total System Memory
4 8 freeSysRam Freee System memory
4 12 totalBackedRam Backed Sample Ram Memory
4 16 freeBackedRam Free Backed Sample Ram Memory
4 20 totalVolRam Total Volatile Sample Ram Memory
4 24 freeVolRam Free Volatile Sample Ram Memory
iClass / iSubClass 1 2345678
1 - Synth Expander S2 S3 S2 Box SK76 SK88
2 - Masterkeyboards MK88
3 - Keyboards WS2 WS1 WX2 WX2Box CD WX400 WK4 SX2 SX3 WK3
4 - Pianos WS400 RPro1 RPro2 RPprox Ps2500 PS1500
5 - Home Organs
6 - Classic Organs
7 - Accessories AS-1
(TAB.1)
Parameter Data. In this case the streams relating to the parameter names requested are returned and all the data is identifed
by the following 16 bytes:
0 1 2 3-15
Parameter ID Bank Select Perf Select Parameter Name (13 char Max)
The parameters bs (bank select) and ps (prChange select) contained in the request vary according to the parameter as in
Tab.2, taking into accound that the request will have effectively followed only in the case in which what has been requested is
actually present in the system; to be able to request all the values available for a given parameter, it is sufficient to send the values
bs=00 e ps=00.
STATUS SOUND REAL PERF. STYLE SONG
Bank Select Range 00 1 - 16 1 - 8 1 - 96 1 - 16
PrCh Select Range 00 1 - 128 not used (nu) nu nu
(Tab.2)