8 KT Owner’s Manual • Installation • Use • Maintenance General Pump is a member of the Interpump Group KT16A, KT18A, KT20A, KT22A Ref 300941 Rev.
GENERAL PUMP INDEX 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. A member of the Interpump Group KT SERIES INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 4 DESCRIPTION OF SYMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 4 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL PUMP INDEX 13. 14. 15 16. 17. 18. A member of the Interpump Group KT SERIES PRECAUTIONS AGAINST FREEZING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 26 WARRANTY TERMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 26 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GENERAL PUMP 1. INTRODUCTION A member of the Interpump Group KT SERIES This manual describes the use and maintenance instructions of the KT Series pump, and should be carefully read and understood before using the pump. Correct use and adequate maintenance will guarantee the pumps trouble-free operation for a long time. General Pump declines any responsibility for damage caused by misuse or the non-observance of the instructions indicated in this manual.
GENERAL PUMP A member of the Interpump Group 3. SAFETY KT SERIES 3.1 General Safety Indications Improper use of pumps and high pressure systems, and the non-compliance with installation and maintenance instructions may cause severe injury to people and/or damage to property.
GENERAL PUMP A member of the Interpump Group KT SERIES Note: appropriate clothing will effectively protect against water spray, but it may not offer adequate protection against the direct impact of water jets or sprays from a close distance. Some circumstances may require further protection. 3. It is generally best to organize personnel into teams of at least two people capable of giving mutual and immediate assistance in case of necessity and of taking turns during long and demanding operation. 4.
GENERAL PUMP 5. TECHNICAL FEATURES MODEL RPM KT16A 1750 KT18A KT SERIES A member of the Interpump Group FLOW RATE PRESSURE GPM l/min 27.4 7,250 500 35.6 26.2 1750 9.2 34.7 5,800 400 36.1 26.5 KT20A 1750 11.4 42.9 4,650 320 35.6 26.2 KT22A 1750 13.7 51.9 3,630 250 33.7 24.8 KT24A 1750 16.4 61.7 2,900 200 32.1 23.6 KT28A 1750 22.2 84.0 2,540 175 38.2 28.0 KT30A 1750 25.4 96.4 2,175 140 35.1 25.8 KT32A 1750 29.1 110.0 1,750 150 35.4 26.
GENERAL PUMP A member of the Interpump Group 6. DIMENSIONS AND WEIGHT KT SERIES For dimensions and weight of KT16A, KT18A, KT20A, KT22A, please refer to fig. 2. fig. 2 For dimensions and weight of KT24A, KT28A, KT30K, KT32A, KT36A, KT40A pumps, please refer to fig. 2a. fig. 2a Ref 300941 Rev.
GENERAL PUMP A member of the Interpump Group 7. OPERATING INSTRUCTIONS KT SERIES The KT pump was designed to operate with filtered water (see paragraph 9.7), in environments that are not potentially explosive and at maximum temperature of 1040 F (400 C). Other fluids may be used only upon the approval of The Customer Service Department . 7.1 WaterTemperature The max water temperature is 1040 F (400 C).
GENERAL PUMP A member of the Interpump Group KT SERIES In any case, oil must be changed at least once a year since it may deteriorate by oxidation. For room temperatures that differ from that mentioned earlier, follow the indications contained in the diagram below, keeping in mind that the oil must have a minimum viscosity of 180 cSt. VISCOSITY/ROOM TEMPERATURE DIAGRAM Exhausted oil must be collected in an appropriate recipient and disposed of in appropriate locations.
GENERAL PUMP A member of the Interpump Group 8. PORTS AND CONNECTIONS KT SERIES KT Series pumps are equipped with (see fig. 4): 1. 2 inlet ports “IN”, 1” NPT (KT16A, KT18A, KT20A, KT22A). 2 inlet ports “IN”, 1-1/4” NPT (KT24A, KT28A, KT30A, KT36A, KT36A, KT40A). Line connection to any of the two ports is indifferent for proper pump functioning. The unused ports must be sealed off. 2. 2 outlet ports “OUT”, 1/2” NPT-F (KT16A, KT18A, KT20A, KT22A).
GENERAL PUMP 9. PUMP INSTALLATION A member of the Interpump Group KT SERIES 9.1 Installation The pump must be installed in a horizontal position using the M12x1.5 threaded support feet. Tighten the screws with a torque of 80 Nm (59 Ft-Lb) The base must be perfectly flat and rigid enough as not to allow bending or misalignment on the pump coupling and axis/transmission due to torque transmitted during operation. The unit cannot be fixed ridgedly to the floor.
GENERAL PUMP KT SERIES A member of the Interpump Group 9.2 Direction of rotation The PTO rotation is indicated by an arrow located on the casing near the drive shaft. From a position facing the pump head, the rotation direction will be as in fig. 5. 9.3 Version Change and Reducer Positioning A right version pump is defined when: observing the pump from the head side, the PTO shank of the pump shaft is on the right side.
GENERAL PUMP A member of the Interpump Group KT SERIES 9.4 Hydraulic Connections In order to isolate the system from the vibrations produced by the pump, we advise to build the first section of the duct near the pump (both for intake and delivery) with flexible hose. The consistency of the intake section must be as such to avoid deformation caused by vacuums produced by the pump. 9.5 Pump Power Supply A positive head of at least 8 inches (.2 meters) is required for the best volumetric efficiency. 9.
GENERAL PUMP A member of the Interpump Group 9.7 Filtering On the suction line, install two filters as indicated in fig. 7 and fig. 7/a. KT SERIES With the manual adjustment valve: With a pneumatically activated control valve The filter must be installed as close as possible to the pump, should allow easy inspection and have the following characteristics: 1. Minimum capacity 3 times greater than the pump’s rated flow value. 2. Filter port diameters must not be smaller than the pump inlet ports. 3.
GENERAL PUMP A member of the Interpump Group KT SERIES 9.8 Outlet Line To obtain a correct delivery line, please comply with the following installation instructions: 1. The internal diameter of the hose must allow to guarantee correct fluid speed; see digram in paragraph 9.9 2. The first section of the hose connected to the pump must be flexible in order to isolate pump vibrations from the rest of the system. 3.
GENERAL PUMP A member of the Interpump Group FOR KT16A, KT18A, KT20A, KT22A: KT SERIES 9.9 Internal Diameter of the Hose Line To determine the internal diameter of the hose, please refer to the following diagram. Suction Hose With a flow rate of ~105 GPM (400 l/mn) and water speed of 1 m/sec. the diagram line that connects the two scales intersects the central scale, indicating the diameters, at a value of ~ 3.5 inch (90 mm). Delivery Hose With a flow rate of ~105 GPM (400 l/mn) and water speed of 5.
GENERAL PUMP A member of the Interpump Group FOR KT24A, KT28A, KT30A, KT32A, , KT36A, KT40A: KT SERIES 9.9 Internal Diameter of the Hose Line To determine the internal diameter of the hose, please refer to the following diagram. Suction Hose With a flow rate of ~105 GPM (400 l/mn) and water speed of 1 m/sec. the diagram line that connects the two scales intersects the central scale, indicating the diameters, at a value of ~ 3.5 inch (90 mm).
GENERAL PUMP A member of the Interpump Group KT SERIES 9.10 V-belt Transmission The pump can be controlled by a v-belt system. For these pumps we recommend use of 3 XPB belts (16.5x13 serrated). Use an XPC profile only for long durations. Both the characteristics and transmissible power of each belt can be verified in the diagram in fig. 7, in relation to the number of RM normally declared by the manufacturer. Minimum duct pulley diameter (on pump shaft): ≥ 6.3” (160 mm).
GENERAL PUMP A member of the Interpump Group KT SERIES Dimensions (in mm) Minimum pulley diameter must be respected. Do not use laminated v-belts. b) Use high performance belts - for example XPB instead of SPB - as a lower quality of belts for the same transmitted power may be necessary and a consequent shorter resulting distance compared to the shaft shoulder (PTO), “a” of fig. 10. Ref 300941 Rev.
GENERAL PUMP A member of the Interpump Group KT SERIES c) Pull the belts according to manufacturer instructions. Excessive pulling can cause reduced bearing life and wear out the pulley prematurely. Pulling depends on different variables as indicated in point 9.12. d) Belt length has a natural tolerance ≥ ± 0.75%. For this reason, the 3 belts must be purchased as a pair. e) Follow the direction of the belt pull as shown in fig. 10; for other needs, contact our Customer Service Department.
GENERAL PUMP A member of the Interpump Group KT SERIES Conclusion: with a wheelbase of 600 mm an with a dynamometer, loading the belt branch with 75 N as indicated in fig. 12, a “te” bend of approximately 10.8 mm is obtained. Note: unless otherwise state by the supplier of he belts, control of proper pull and its relative re-tensioning should be performed after no less than 30 minutes of motion necessary for the normal adjustment of the belts.
GENERAL PUMP A member of the Interpump Group 9.13 Transmission of power from the second PTO KT SERIES Upon request, KT pumps can be supplied with auxiliary PT on the side opposite of the drive (Transmission of power from the second PTO). Transmission can be carried out: • By means of the V belts • By means of the joint By means of the V-belt, withdrawable Max Torque is: 15 ft. lbs (20 Nm) which corresponds to: 4.1 Cv to 1450 RPM 5.
GENERAL PUMP A member of the Interpump Group 10. START-UP AND OPERATION KT SERIES 10.1 Preliminary Inspections Before Start-up Be sure that: The suction line is connected and up to pressure (see Chapter 9) the pump must never run dry. 1. The suction line must be perfectly airtight. 2. All the On-Off valves between the pump and the feeding source are completely open. The delivery line must discharge freely in order to allow the air in the pump to be expulsed easily, thus facilitating pump priming. 3.
GENERAL PUMP KT SERIES A member of the Interpump Group 11. PREVENTATIVE MAINTENANCE To guarantee pump reliability and efficiency, comply with the maintenance intervals as indicated in the table below. PREVENTATIVE MAINTENANCE EVERY 500 HOURS Check oil level EVERY 1000 HOURS Check / • • • • Change oil Replace:* Valves Valve seats Valve springs Valve guides Check / Replace: • H.P packings • L.P. packings * For replacement follow instructions contained in the repair manual. Ref 300941 Rev.
GENERAL PUMP A member of the Interpump Group 12. PUMP STORAGE KT SERIES 12.1 Long-term Inactivity If the pump is started for the first time after a long period from the date of shipment, before operation, check the oil level, inspect the valves as specified in Chapter 10, then follow described star-up procedures. 12.1 Filling the Pump With An Anti-Corrosion Emulsion or Anti-freeze By Using An External Diaphragm Pump As In The Layout Shown in Paragraph 9.7.
GENERAL PUMP A member of the Interpump Group 15.
GENERAL PUMP A member of the Interpump Group 16. EXPLODED VIEW AND PARTS LIST KT16A/18A/20A/22A SERIES Ref 300941 Rev.
GENERAL PUMP Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 40 41 42 Part # F70010022 Description Crankcase F91847700 Tapered Roller Bearing F70220081 Shim, 0.
GENERAL PUMP A member of the Interpump Group REPAIR KITS KIT NUMBER Positions Included F2227 Plunger Packing Kit KT16A 37, 39, 41, 42, KIT NUMBER F2031 Inlet Valve Kit KT16/18A Positions Included 68, 85 KIT NUMBER F2231 Complete Seals Kit KT16 F2228 Plunger Packing Kit KT18A 37, 39, 41, 42, F2229 Plunger Packing Kit KT20A 37, 39, 41, 42, KT16A/18A/20A/22A SERIES F2230 Plunger Packing Kit KT22A 37, 39, 41, 42, F2022 F0150 F2023 Inlet Valve Kit Outlet Valve Kit Outlet Valve Kit KT20/22A KT16/18A
GENERAL PUMP A member of the Interpump Group 16. EXPLODED VIEW AND PARTS LIST KT24A/28A/30A/22A/36A/40 SERIES Ref 300941 Rev.
GENERAL PUMP Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 34 35 36 37 38 39 40 Part # F70010022 F91847700 F90391500 F70220081 F70220381 F90075600 F70211801 F90387700 F70150122 F99185400 F90383300 F98210050 F98211500 F72210695 F90360400 F70160622 F90394200 F98200500 F99312300 F70020635 F91490000 F70150022 F90166800 F90167700 F96709900 F70040209 F70040309 F70040409 F70041309 F70040509 F70041209 F90358400 F70224136 F70050015 F97742000 F90910000 F90922000 F9092
GENERAL PUMP REPAIR KITS KIT NUMBER F2006 Plunger Packing Kit KT24A Positions Included 37, 39, 41, 42 KIT NUMBER F2246 Inlet Valve Kit KT24A/28A 30A/32A Positions Included KT24A/28A/30A/22A/36A/40 SERIES A member of the Interpump Group F2008 Plunger Packing Kit KT28A 37, 39, 41, 42 F2019 Plunger Packing Kit KT30A 37, 39, 41, 42 F2248 Plunger Packing Kit KT32A 37, 39, 41, 42 F2133 Plunger Packing Kit KT36A 37, 39, 41, 42 F2249 Plunger Packing Kit KT40A 37, 39, 41, 42 F2247 F2246 Inlet Valv
GENERAL PUMP A member of the Interpump Group 16. FLUSHING CIRCUIT DIAGRAM OF USE KT SERIES Ref 300941 Rev.
GENERAL PUMP A member of the Interpump Group 18. MAINTENANCE LOG KT SERIES HOURS & DATE OIL CHANGE GREASE PACKING REPLACEMENT PLUNGER REPLACEMENT VALVE REPLACEMENT GP Companies, Inc. 1174 Northland Drive Mendota Heights, MN 55120 Phone:651.686.2199 Fax: 800.535.1745 www.generalpump.com email: sales@gpcompanies.com Ref 300941 Rev.