User Manual

GENERAL PUMP
A member of the Interpump Group
KT SERIES
Page 23
Ref 300941 Rev.A
03-14
9.13 Transmission of power from the second PTO
Upon request, KT pumps can be supplied with auxiliary PT on the side opposite of the drive (Transmission of power
from the second PTO).
Transmission can be carried out:
By means of the V belts
By means of the joint
By means of the V-belt, withdrawable Max Torque is:
15 ft. lbs (20 Nm) which corresponds to:
4.1 Cv to 1450 RPM
5.0 Cv to 1750 RPM
By means of the joint, withdrawable Max Torque is:
30 ft. lbs. (40 Nm) which corresponds to:
8.2 Cv to 1450 RPM
10 Cv to 1750 RPM
By means of the V-belt, the transmission is considered suitable if:
Belt pull is applied at a max distance of .7” (18 mm) from the bend shaft shoulder (see fig. 13). Min. diameter
pulley to be used = Ø 4” (100 mm).
With transmission by means of the joint, pay particular attention to perfect alignment so that no transverse
forces are generated on the pump shaft.
For applications differing from those specified above, contact our Customer Service Department.