Apply two supports with G2” threading to the outlet connections of the head (pos. 1, fig. 104) and then
unscrew the 8 M16X150 screws (pos. 1, fig. 105). Take care to not subject the plungers to knocks or bumps
when taking them out of the head.
Unscrew and remove the 8 M16X55 screws of the valve cover (pos. 1, fig. 106) and remove the cover
(pos. 1, fig. 107).
Remove the valve plug by using a slide hammer puller applied to the M10 hole in the valve plug (pos.1,
fig. 108).