SH Owner’s Manual • Installation • Use • Maintenance
GENERAL PUMP INDEX A member of the Interpump Group SH SERIES 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3 3. SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3.1 General warnings for safe operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3.2 High pressure unit safety requirements . . . . . . . . . . . . . . . . . . . . . .
GENERAL PUMP 1. INTRODUCTION A member of the Interpump Group SH high pressure water plunger pumps have been designed for long life industrial duties and provided they are correctly installed and maintained will give long trouble-free operation. Read and understand this manual before using your pump; it contains the necessary information for the correct installation, use and maintenance as well as some practical suggestion for trouble shooting.
GENERAL PUMP A member of the Interpump Group 3.3 Safety of operation The access into the area when a high pressure unit is working should be strictly prohibited to unauthorized personnel. The area should be suitably enclosed and its perimeter, so far as is reasonably practical, cordoned off and proper warning notices displayed in prominent positions.
GENERAL PUMP 4. PUMP IDENTIFICATION SH SERIES A member of the Interpump Group Each pump is fitted with a rating plate (see Fig. 1) containing the following information: 2. 3. 4. 5. 6. 7. 8. pump model and version serial number max RPM max operating pressure (bar) oil capacity (ltr) and oil specification gear box ratio max flow rate (l/min) Pump model, pump version and serial number should be specified when ordering spare parts. Should the pump be modified (i.
GENERAL PUMP A member of the Interpump Group 7. GENERAL INFORMATION ABOUT PUMP USE SH SERIES 8. CONNECTIONS AND PLUGS The SH pump has been designed to pump fresh filtered water at room temperature. 7.1 Water temperature The max water temperature is 30oC (86oF) 7.2 Max flow and pressure ratings The performance data indicated in the catalog and on the rating plate refer to the maximum performance of the pump.
GENERAL PUMP 9. PUMP INSTALLATION A member of the Interpump Group 9.1 Positioning The pump should be installed flat on a rigid base by means of the four Ø 19mm feet. The base should be rigid enough to avoid any misalignment or flexing of the pump/transmission coupling axis due to the torque involved during operation. 9.2 Direction of rotation Fig. 5 shows the correct direction of rotation looking at the pump from the fluid end side.
GENERAL PUMP A member of the Interpump Group 9.5 Filtration SH pumps require 10 to 20 microns water filtration degree. For a correct filtration system three individual filter units should be provided and positioned as shown in Fig. 6. The filters should be installed as close as possible to the pump, allow easy inspection and have the following specifications: a. Capacity of each filter should be at least three times the rated pump flow rate. b.
GENERAL PUMP SH SERIES A member of the Interpump Group 10.3 Water cooling system During operation the cooling water is drained out of the pump though the port (4, Fig. 7) located underneath the pump head. The cooling water line should be connected to the inlet line BEFORE the feed pump as shown below. 11. MAINTENANCE INSTRUCTIONS 11.1 Crank mechanism maintenance. Check oil level though the oil level indicator (1, Fig. 8) at least on a weekly basis. If necessary, top up from the oil plug 3, Fig. 8.
GENERAL PUMP A member of the Interpump Group 11.2 Fluid end maintenance The fluid end does not require periodical maintenance. Service operations are limited to valve inspection and/or replacement, when necessary. SH SERIES Remove the pump head. (Fig. 12) In order to have access to the delivery valves loosen the 12 valve cover screws (1, Fig. 9) and remove the covers. Once removed take out the delivery valve guide with the spring and valve poppet.
GENERAL PUMP A member of the Interpump Group Reassemble valves and head back in place by following the disassembling steps in the opposite sequence and use a torque wrench at the following settings for valve cover screws and head screws: -Valve cover screw: 144.6 ft. lbs. -Head screws: 397.8 ft. lbs. NOTE: In order to facilitate reassembling operation use our tool 1, Fig.
GENERAL PUMP A member of the Interpump Group Remove the upper cover (1, Fig. 20). Once head and collector are removed the cylinders (1, Fig.21) are free to be taken out of the pump body. Tapping the cylinders all around with a plastic hammer helps to loosen them from possible scaling or deposit accumulated during operation. Once the cylinders are removed, loosen the plungers and check them for wear (Fig 22). Replace if necessary. SH SERIES Remove the seeger (1, Fig. 23).
GENERAL PUMP A member of the Interpump Group SH SERIES The new rear seal should be mounted with the larger diameter side first in, as shown in Fig. 28. Fit each new component of the pressure packing set in the cylinder making sure of the correct order as shown in Fig 26: 1. Packing bushing 2. Packing ring 3. Back packing 4. Pressure Packings 5.
GENERAL PUMP A member of the Interpump Group 12. SCREW CALIBRATION Screw calibration is to be carried out by means of a torque wrench only: DESCRIPTION Ft. Lbs. Head Bolts 397.8 Valve cover screws Plunger bolts Connecting Rod Screws N-m Kgm. 539.3 55 144.6 196.1 72.3 98 54.2 13. MAINTENANCE TOOLS 73.5 20 10 7.
GENERAL PUMP A member of the Interpump Group 16.
GENERAL PUMP Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Part # Description F010100070 Left bearing support F881010133 F030000010 F881010132 F871121152 F063400280 F871131102 F030000020 F811111017 F871125154 F871115152 F040400050 F080600030 F872043008 F821203006 F801053012 F872043002 F801057002 F063400240 F080600010 F060100160 F881010116 F801054027 F872026003 F
GENERAL PUMP A member of the Interpump Group 17. TROUBLE SHOOTING SH SERIES THE PUMP DOES NOT PRODUCE ANY NOISE: the pump is not primed and is running dry! - No water in the inlet line - The valves are blocked - The pressure line is closed and does not allow the air to get out the fluid end. INSUFFICIENT PUMP PRESSURE: - The nozzle is (or has become) too large.
GENERAL PUMP MAINTENANCE LOG A member of the Interpump Group SH SERIES HOURS & DATE OIL CHANGE GREASE PACKING REPLACEMENT PLUNGER REPLACEMENT VALVE REPLACEMENT GP Companies, Inc. 1174 Northland Drive Mendota Heights, MN 55120 Phone:651.686.2199 Fax: 800.535.1745 www.generalpump.com email: sales@gpcompanies.com Ref 300032 Rev.