Repair Manual Owner's manual
GENERAL PUMP
A member of the Interpump Group
SM SERIES
Couple the half supports to the previously disassembled caps, referring to the numbering (1, fig. 40).
Page 14
To separate the rod from the plunger guide, unscrew the hexagonal head M10 screws with a 17 socket
wrench (1, fig. 41), blocking the rod with the 36 fork spanner.
Ref 300894 Rev.A