Separate the pinion from the cover, working with an extractor hammer on the pinion itself (1, fig. 8)
Remove the Seeger ring Ø 55 (1, fig. 9) and the bearing support ring (1, fig. 10) from the pinion.
Extract the seal ring from the reduction gear cover, working from the inner side of the cover (1, fig. 11).
Ref 300894 Rev.A