Owner's manual
Optional Type K thermocouple probe.
Accessories AC to DC 9V adapter.
RS232 cable, UPCB-02.
Data Acquisition software,SW-U801-WIN.
Data Logger software, SW-DL2005.
2-2 Electrical Specifications (23± 5  )℃
Air velocity
 Measurement Range Resolution Accuracy
 m/S 0.4 - 30.0 m/S  0.1 m/S  ± ( 2%+0.2 m/S)
 Km/h  1.4 - 108.0 Km/h 0.1 Km/h ± ( 2%+0.8 Km/h)
 Mile/h  0.9 - 67.0 Mile/h  0.1 Mile/h ± ( 2%+0.4 Mile/h)
 Knots  0.8 - 58.3 Knots 0.1 Knots ± ( 2%+0.4 Knots)
 Ft/min  80 - 5910 Ft/min  1 Ft/min  ± ( 2%+40 Ft/min)
Air flow
 Measurement Range Resolution Area
CMM (m^3/min.)  0 to 54,000 m^3/min. 0.001-1 0.001-30.0 m^3/min.
CFM (ft^3min.). 0 to 1,908,300 ft^3/min. 0.01-100 0.01-322.91 ft^3/min.
Air temperature
Measuring Range 0   to 50  /32   to 122 ℃℃℉ ℉
Resolution 0.1 /0.1 ℃℉
Accuracy ±  0.8  /1.5 ℃℉
4